Skip to main content
Schneider Electric C10W36E100

Schneider C10W36E100 ComPacT NSX MCCB, 100 A, 100 kA ICu, MicroLogic 6.2 E

MPN C10W36E100
Active

Schneider C10W36E100 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.

$13.51 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10W36E100 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C10W36E100 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Overview

The C10W36E100 is a Schneider ComPacT NSX molded case circuit breaker rated 100 A continuous with a 100 kA interrupting capacity at 690 V AC, fitted with a MicroLogic 6.2 E electronic trip unit providing LSI/G protection (long-time, short-time, instantaneous, ground fault). The trip unit includes an LCD display for metering and event logging, and the breaker carries EN/IEC 60947-2 compliance with a Class II front face.

The 100 kA ICu at 690 V AC suits high-fault-current distribution panels where a standard 85 kA frame would require upstream fusing or a larger transformer — the C10W36E100 handles the full fault without coordination add-ons. Compared to the C10F3TM025 (85 kA ICu, 25 A fixed thermal-magnetic), the C10W36E100 delivers 100 kA ICu and 100 A adjustable electronic protection, making it the right choice for a main feeder or large subfeed where selectivity and metering are required.

MPN
C10W36E100