Skip to main content
Schneider Electric C114100LS

Schneider Electric C114100LS ComPacT NSXm 100NA Switch Disco

MPN C114100LS
Active

Schneider Electric ComPacT NSXm 100NA, switch disconnector, 4 poles, Ith 100 A at 40 °C, 440 V AC, EverLink lugs, toggle control, IP40, IK07.

$264.70 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C114100LS key specifications
ParameterValue
Control typeToggle
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
CurrentAC-23: 100 A AC 50/60 Hz AC-22: 100 A AC 50/60 Hz
Utilization categoryAC-22 A AC-23 A
IP ratingIP40
Terminal pitch27 mm
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

C114100LS additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth80 mm
Width108 mm
Height137 mm
Electrical life cyclesAC-22 A: 20000 cycles 440 V AC 50/60 Hz Ie/2 AC-23 A: 20000 cycles 440 V AC 50/60 Hz Ie/2 AC-22 A: 10000 cycles 440 V AC 50/60 Hz Ie AC-23 A: 10000 cycles 440 V AC 50/60 Hz Ie
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C114100LS is a ComPacT NSXm 100NA switch disconnector, 4 poles, rated 100 A in both AC-22 and AC-23 utilisation categories at 440 V AC 50/60 Hz. It is suited for isolation per EN/IEC 60947-3, with a visible break indicator and toggle control. The 100 A thermal current (Ith) at 40 °C means it handles full-rated resistive and moderately inductive loads without derating in a 40 °C panel ambient.

Rated operational current is 100 A in both AC-22 (switching mixed resistive and inductive loads, including moderate overloads) and AC-23 (switching motors or other highly inductive loads). That 100 A holds at 440 V AC — no derating needed for the voltage step. Short-time withstand (Icw) is 1500 A for 1 s or 3 s, and 335 A for 20 s, which covers downstream fault clearing coordination. Short-circuit making capacity (Icm) is 2.13 kA as a stand-alone switch-disconnector, or 150 kA with an upstream protection circuit breaker — so it can be paired with a fast-acting breaker upstream for high-fault-current installations. That puts it in the standard industrial panel category — no special creepage or clearance needed for most 400 V distribution.

Fixed mounting mode, 108 mm wide, 137 mm tall, 80 mm deep — fits a standard 4-pole disconnector footprint. Connection pitch 27 mm, terminals accept EverLink lugs: 2.5…70 mm² flexible copper, or 2.5…95 mm² rigid/stranded aluminium/copper. IP40 front face, IK07 impact resistance. Operating temperature -25…70 °C, storage -50…85 °C.

MPN
C114100LS