Skip to main content
Schneider Electric C11E34V050L — Residual Current Breakers (RCCB/RCBO)

C11E34V050L ComPacT NSXm 50A Earth Leakage MCB, 16kA

MPNC11E34V050L
Active

Schneider Electric ComPacT NSXm, 3P, 50 A, MicroLogic 4.1 electronic trip unit, 16 kA at 415 V AC, earth leakage protection, grey (RAL 7016).

$636.42 – $1,327.86Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E34V050L — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC
Earth-leakage protection class / typeClass A Class AC
Trip unit technologyElectronic
Local signalling / indicationFlag (green) for presence of auxiliary contacts
C11E34V050L — Electrical Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (operating cycles)20000 cycles
C11E34V050L — Identification
ParameterValue
Product nameComPacT NSXm
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSXm 63E
C11E34V050L — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
Width in 9 mm modules9 module
C11E34V050L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude2000 m without derating 5000 m with derating
C11E34V050L — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C11E34V050L is a Schneider Electric ComPacT NSXm earth leakage circuit breaker with a 50 A MicroLogic 4.1 electronic trip unit, rated 16 kA at 415 V AC. It's a 3-pole unit in the grey (RAL 7016) enclosure, designed for distribution panelboards where you need both overcurrent and earth leakage protection in one device. That matters on motor or transformer feeders where repeated reclosing can damage windings.

If your panel runs hotter, you derate per the IEC 60947-2 thermal curve — standard practice for any enclosed distribution board. That is the 'E' performance level in Schneider's naming. Earth leakage sensitivity is selectable from 30 mA up to 5 A, for both class A (pulsating DC) and class AC (sinusoidal AC) fault types. That range covers everything from personnel protection (30 mA) to fire protection (300 mA) to equipment protection (1–5 A) on a single breaker — just dial in the sensitivity that matches your circuit's leakage budget.

Mounts on a backplate in either horizontal or vertical orientation, flat against the panel. The 9-module width (108 mm) fits standard DIN-rail enclosures, though the breaker itself clips to a backplate, not a DIN rail. Front-facing terminals on both line and load sides simplify busbar connections and cable dressing in a distribution board. IP40 front face and IK07 impact rating mean it's protected against tools and small solids in the panel, but it's not washdown-rated — keep it inside a dry enclosure, not on the plant floor exposed to hose spray.

Frequently asked questions

What is C11E34V050L's breaking capacity?

16 kA at 415 V AC, performance level E per Schneider's naming. That's the maximum fault current it can safely interrupt at that voltage.

What compliance documentation does this breaker carry?

Designed and certified to EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, overvoltage category IV. The MicroLogic trip unit provides integrated earth-leakage protection with selectable sensitivity from 30 mA to 5 A for both class A and class AC fault types.

MPN
C11E34V050L