Skip to main content
Schneider Electric C11E6TM016B — Miniature Circuit Breakers (MCB)

C11E6TM016B ComPacT NSXm 4P 16A TM-D, 16 kA 415 V AC

MPNC11E6TM016B
Active

Schneider Electric ComPacT NSXm, 4P thermal-magnetic circuit breaker, 16 A at 40 °C, 16 kA 415 V AC, toggle control, grey (RAL 7016).

$419.26Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E6TM016B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E6TM016B — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E6TM016B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E6TM016B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11E6TM016B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E6TM016B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E6TM016B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E6TM016B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 4P (4-pole) switching with neutral left matches standard 3-phase + N busbar layouts. The breaker is category A (no intentional short-time delay), so it's for instantaneous trip coordination, not selective with downstream breakers.

This breaker is designed for distribution in commercial and industrial panels — backplate-mounted, front-connected, with compression lug or busbar terminals. The IP40 front face and IK07 impact rating suit indoor switchgear where occasional tool contact is possible. Pollution degree 3 (IEC 60664-1) means it handles conductive pollution typical in industrial environments. The 12-module 9 mm pitch (108 mm wide) fits standard DIN-rail enclosures.

Frequently asked questions

Who supplies C11E6TM016B and how is it quoted for volume purchases?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is C11E6TM016B's listed range?

The range is ComPacT, and the product name is ComPacT NSXm.

What compliance documentation does this brand provide for C11E6TM016B?

The breaker is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. Specific RoHS/REACH/UL documentation should be requested at quote time.

MPN