Schneider Electric C11E6TM016L — Miniature Circuit Breakers (MCB)

Schneider C11E6TM016L ComPacT NSXm 16A 4P MCCB, 16 kA

MPNC11E6TM016L
Active

Schneider Electric ComPacT NSXm, C11E6TM016L, 4P thermal-magnetic MCCB, 16 A at 40 °C, 16 kA at 415 V AC, EN/IEC 60947-2.

$427.90Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E6TM016L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E6TM016L — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E6TM016L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E6TM016L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11E6TM016L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E6TM016L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E6TM016L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E6TM016L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C11E6TM016L is a ComPacT NSXm 63E frame circuit breaker, 4-pole, with a TM-D thermal-magnetic trip unit rated 16 A at 40 °C. Mounts on a backplate in horizontal or vertical orientation; the 12-module 9 mm pitch (108 mm wide) and 137 mm height fit standard enclosure cutouts. Front connections top and bottom simplify bus-bar alignment and cable dressing.

Trip unit and protection characteristics

Rated 16 A at 40 °C; no derating required at that ambient for continuous load. For motor branch circuits, pair it with a contactor and overload relay upstream or downstream as the coordination study dictates. No additional creepage or clearance derating needed in standard enclosures.

Durability and environmental ratings

Mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles at 440 V In/2, 10,000 cycles at 440 V In, 10,000 cycles at 690 V In/2, and 5,000 cycles at 690 V In. This covers frequent manual switching for isolation or maintenance — not daily load-break duty, but well above a basic service breaker. IP40 enclosure protection (finger-safe) and IK07 impact resistance (2 J) suit it for general-purpose indoor panels. The grey RAL 7016 finish is standard for Schneider switchgear ranges. Operating altitude to 2000 m without derating, 5000 m with derating. Relative humidity 0–95 % non-condensing. These cover most low- to mid-altitude installations without special provisions.

Everlink lug terminals accept one conductor per side: 2.5–95 mm² rigid or stranded aluminium/copper, or 2.5–70 mm² flexible copper. The 35 mm connection pitch (27 mm without spreaders) matches standard bus-bar centres. Neutral is on the left.

Frequently asked questions

Where can I buy C11E6TM016L and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not listed here.

What is the closest alternative to C11E6TM016L in the ComPacT family?

Within the ComPacT NSXm 63E frame, the primary variant difference is the trip rating. A 16 A TM-D unit is the spec; a 20 A or 25 A TM-D unit (different order code) would be the next step up if the load requires more headroom. No pin-compatible drop-in exists at a different rating — the trip unit is integral to the breaker.

What compliance documentation does Schneider provide for C11E6TM016L?

The breaker is certified to EN/IEC 60947-2. Schneider typically provides a Declaration of Performance (DoP) and CE declaration for EU markets. For RoHS/REACH compliance, refer to the manufacturer's product environmental profile (PEP) available via Schneider's EcoPAS portal.