Schneider Electric ComPacT NSXm, C11E6TM032B, 32 A at 40 °C, 4P, 16 kA at 415 V AC, thermal-magnetic TM-D trip unit, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E6TM032B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E6TM032B — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E6TM032B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E6TM032B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11E6TM032B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E6TM032B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E6TM032B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E6TM032B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

32 A thermal-magnetic MCCB for distribution panels

The 4P configuration with left-side neutral suits panel layouts that keep the neutral switched.

Category A utilisation (no intentional short-time delay) means it's for instantaneous-only protection, typical for feeder and branch circuits in distribution. IP40 front face and IK07 impact resistance let it live in a lockable enclosure or backplate-mounted panel where tools and debris are present but washdown isn't.

Mounts flat on a backplate in horizontal or vertical orientation. The 108 mm width occupies 12 modules of 9 mm pitch on a DIN-rail-compatible backplate. Front connection top and bottom accepts compression lugs or busbars; connection pitch is 35 mm with spreaders, 27 mm without. The toggle handle and green flag for auxiliary contact presence are visible through the IP40 front.

Frequently asked questions

Where can I buy C11E6TM032B and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of C11E6TM032B?

Performance level E: 16 kA at 415 V AC per IEC 60947-2.

What standards does C11E6TM032B comply with?

It is designed and tested to EN/IEC 60947-2, with suitability for isolation confirmed to that standard. Pollution degree 3 per IEC 60664-1, IP40 per IEC 60529, IK07 per IEC 62262.