C11F34V100L key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11F34V100L additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryF 36 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11F34V100L is a ComPacT NSXm MCCB rated 100 A at 40 °C, 3-pole, with a 36 kA interrupting capacity at 415 V AC (performance level F). It uses an electronic MicroLogic 4.1 trip unit and integrates earth-leakage protection — so this single device handles both overcurrent and ground-fault detection in a distribution panel.

For a panel that runs hotter — say 50 °C — you derate per the manufacturer's curve; the electronic trip unit compensates thermally with a 20-minute memory before and after tripping, so nuisance trips on a warm restart are less likely. If upstream fault current exceeds this, a current-limiting device is needed. Integrated earth-leakage protection means the breaker itself includes a residual-current detection coil — no separate RCCB needed. Sensitivity is selectable from 30 mA up to 5 A, for class A or class AC waveforms. For a petrochemical environment where you need to protect against both sinusoidal and pulsating DC fault currents, class A (30 mA to 1 A) is the right choice; class AC covers sinusoidal only.

Overvoltage category IV — suitable for main distribution boards at the service entrance. IP40 front face, IK07 impact resistance. The grey RAL 7016 finish is standard for the ComPacT range.