Skip to main content
Schneider Electric C11F44V050L

C11F44V050L ComPacT NSXm 4P 50A MCB, 36kA 415V AC

MPN C11F44V050L
Active

Schneider Electric ComPacT NSXm, 4P, 50 A, 36 kA at 415 V AC, MicroLogic 4.1 electronic trip unit with integrated earth-leakage, Grey (RAL 7016), IP40.

$781.37 – $800.01 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11F44V050L key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11F44V050L additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryF 36 kA 415 V AC
Operating temperature-25...70 °C

Product details

The C11F44V050L is a Schneider Electric ComPacT NSXm 4-pole MCCB rated 50 A at 40 °C, with a MicroLogic 4.1 electronic trip unit and integrated earth-leakage protection. The toggle control and front-facing connections make it straightforward to wire into a distribution panel mounted on a backplate. EN/IEC 60947-2 compliance covers the application standard for circuit-breakers in industrial and commercial power systems.

Overvoltage category IV means it's rated for installation at the origin of the installation, not just downstream sub-distribution. Pollution degree 3 (IEC 60664-1) confirms it tolerates conductive pollution typical in industrial panels — no special conformal coating needed. The integrated earth-leakage protection covers both class A and class AC sensitivities from 30 mA up to 5 A — selectable via the trip unit settings. That saves an external RCCB module and one DIN-space.

No DIN-rail clip; it's bolted through the mounting holes. The 4-pole footprint is 12 modules of 9 mm pitch (108 mm wide), 144 mm tall, 80 mm deep. Connection pitch is 35 mm with spreaders, 27 mm without — so busbar or cable lugs need to match. Everlink terminals accept 2.5–70 mm² fine-stranded copper or 2.5–95 mm² rigid/stranded aluminium/copper. Neutral is on the left. IK07 impact rating handles a 2 J blow (roughly a hammer tap) without cracking the case. The local signalling flag shows green when auxiliary contacts are present — a quick visual check without opening the door.

MPN
C11F44V050L