Skip to main content
Schneider Electric C11H6TM016B — Miniature Circuit Breakers (MCB)

Schneider Electric C11H6TM016B ComPacT NSXm 4P 16A 70kA MCCB

MPNC11H6TM016B
Active

Schneider Electric ComPacT NSXm, C11H6TM016B, 4-pole MCCB, 16 A at 40 °C, 70 kA breaking capacity at 415 V AC, thermal-magnetic TM-D trip unit, EN/IEC 60947-2.

$646.49Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H6TM016B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H6TM016B — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H6TM016B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11H6TM016B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H6TM016B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H6TM016B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H6TM016B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11H6TM016B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What the 70 kA breaking capacity means for your panel

The C11H6TM016B is a Schneider Electric ComPacT NSXm moulded-case circuit breaker rated 16 A at 40 °C with a 70 kA breaking capacity at 415 V AC (performance level H). At 4 poles and 12-module pitch (108 mm wide), this breaker occupies a full-width position on a backplate or DIN-rail adapter. The 80 mm depth and 137 mm height fit standard distribution enclosures; the grey (RAL 7016) housing is the standard Schneider finish for the ComPacT NSXm family. Connection is front-to-front via compression lugs or busbars, with a 35 mm pitch (27 mm without spreaders).

Installation and environmental constraints

The 12-module pitch (108 mm wide) means it fills a standard 12-module DIN-rail space if using an adapter. Connection pitch is 35 mm with spreaders, 27 mm without — so if you are paralleling busbars across multiple breakers, match the pitch to your busbar hole spacing. IP40 front protection (IK07 impact) keeps tools and fingers out but is not sealed against hose-down; install in a clean, dry enclosure. Operating altitude is 2000 m without derating, up to 5000 m with derating — relevant for high-altitude sites where air density reduces arc-quenching effectiveness.

Mechanical durability is 20 000 cycles; electrical durability varies with load — 20 000 cycles at 440 V at half rated current (In/2), 10 000 cycles at 440 V at full rated current, and 5000 cycles at 690 V at full rated current. For a distribution breaker that sees infrequent switching (once a day or less), these numbers translate to decades of service. The toggle control gives positive manual open/close indication; the local signalling flag (green) shows presence of auxiliary contacts.

Frequently asked questions

Where can I buy C11H6TM016B and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to get a firm lead-time and price.

What is the breaking capacity of C11H6TM016B?

70 kA at 415 V AC (performance level H). That is the maximum fault current it can safely interrupt at that voltage.

What standards does C11H6TM016B comply with?

It is designed and tested to EN/IEC 60947-2, with suitability for isolation per that standard. Pollution degree 3 and overvoltage category III per IEC 60664-1.

MPN
C11H6TM016B