Schneider Electric C11H6TM016L — Miniature Circuit Breakers (MCB)

Schneider Electric C11H6TM016L ComPacT NSXm 16A 4P MCCB, 70

MPNC11H6TM016L
Active

Schneider Electric ComPacT NSXm, 4P, 16 A, TM-D trip, 70 kA at 415 V AC, EN/IEC 60947-2, grey (RAL 7016).

$273.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H6TM016L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H6TM016L — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H6TM016L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11H6TM016L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H6TM016L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H6TM016L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H6TM016L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11H6TM016L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Panel-builder commissioning notes

The C11H6TM016L is a 4-pole ComPacT NSXm MCCB with a 16 A thermal-magnetic TM-D trip unit, rated for distribution duty. The 108 mm width and 137 mm height occupy 12 module pitches at 9 mm — plan the gland plate and busbar layout accordingly. IK07 impact rating handles accidental tool drops during commissioning. Everlink terminals accept 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper. Connection pitch is 35 mm with spreaders, 27 mm without — torque the lugs to the manufacturer's spec; the aluminium rating means you can land a feeder from an older installation without a pin adapter.

If your panel runs hotter, derate per the thermal curve — the TM-D unit is thermal-magnetic, so the thermal element responds to ambient temperature. The green flag signals presence of auxiliary contacts — useful for remote status indication without opening the door. Electrical durability is 20,000 cycles at 440 V at half rated current, 10,000 cycles at full rated current. For a distribution breaker these numbers are typical — not a wear item you cycle daily, but fine for occasional switching and fault clearing over the panel's service life.

Frequently asked questions

What is the breaking capacity of C11H6TM016L?

70 kA at 415 V AC, performance level H, per EN/IEC 60947-2.

What terminals does C11H6TM016L use?

Everlink lugs accepting 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper.

MPN
C11H6TM016L