Schneider Electric C11H6TM040B — Miniature Circuit Breakers (MCB)

Schneider Electric C11H6TM040B ComPacT NSXm Circuit Breaker,

MPNC11H6TM040B
Active

Schneider Electric ComPacT NSXm, C11H6TM040B, 4P thermal-magnetic circuit breaker, 40 A at 40 °C, 70 kA at 415 V AC, IP40, grey RAL 7016.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H6TM040B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H6TM040B — Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H6TM040B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11H6TM040B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H6TM040B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H6TM040B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H6TM040B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11H6TM040B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The thermal-magnetic trip unit (TM-D) handles overloads and short-circuits in one package; no separate relay needed. Rated for distribution duty per EN/IEC 60947-2, Category A, with suitability for isolation. IK07 impact rating handles accidental tool bumps during commissioning.

Mounts on a backplate — horizontal or vertical, flat on the back. 12-module pitch at 9 mm per module (108 mm wide, 137 mm high, 80 mm deep). Connection pitch is 35 mm with spreaders, 27 mm without. Toggle control, grey (RAL 7016) housing. Local flag (green) indicates presence of auxiliary contacts. Earth-leakage protection is not built in — specify an external Vigi module if needed.

Listed as current production.

Frequently asked questions

What is the breaking capacity of C11H6TM040B?

70 kA at 415 V AC (performance level H), per IEC 60947-2.

What compliance documentation does Schneider provide for C11H6TM040B?

The breaker is certified to EN/IEC 60947-2, with IP40 per IEC 60529 and IK07 per IEC 62262. Pollution degree 3 per IEC 60664-1. RoHS/REACH declarations are standard from Schneider for this series.