Schneider Electric C125N360FM — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C125N360FM ComPacT NS, 1250 A, 50 kA at 4

MPNC125N360FM
Obsolete

Schneider Electric ComPacT NS new generation, C125N360FM, 3P 1250 A circuit breaker with MicroLogic 6.0 electronic trip unit, 50 kA Icu at 415 V AC, fixed mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C125N360FM — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C125N360FM — Electrical Ratings
ParameterValue
Rated current (In)1250 A at 50 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Number of poles3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Overvoltage categoryIII
Electrical durability2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (operating cycles)10000 cycles
C125N360FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product / component typeCircuit breaker
Product range / familyComPacT
C125N360FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
C125N360FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C125N360FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C125N360FM is a 3-pole ComPacT NS new generation circuit breaker rated 1250 A at 50 °C, with a MicroLogic 6.0 electronic trip unit. This is a distribution breaker, not a motor-protection device — the LSI protection curve (long-time, short-time, instantaneous) is set for feeder or main switchboard duty. The MicroLogic 6.0 trip unit provides electronic overload (L), short-time short-circuit (S), and instantaneous (I) protection, with a 20-minute thermal memory that prevents nuisance reclosing after a thermal trip. Earth-leakage protection is not integrated — specify an external Vigi module if ground-fault detection is needed.

Physical integration and environment

Fixed-mount, backplate installation. Dimensions: 327 mm high, 210 mm wide, 147 mm deep. Connection pitch is 70 mm; both upside and downside connections are front-accessible. Power losses are 44 W at rated current — factor that into panel thermal calculations.

Frequently asked questions

What is C125N360FM's breaking capacity at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That is the N breaking capacity code — suitable for most industrial distribution panels with a 415 V supply.

What protection curves does the MicroLogic 6.0 trip unit provide?

LSI: long-time overload (L), short-time short-circuit (S), and instantaneous (I). No ground-fault (G) protection is built in — add an external Vigi module if needed.

Where can I buy C125N360FM?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window.