Schneider Electric C125N360FM

Schneider Electric C125N360FM ComPacT NS, 1250 A, 50 kA at 4

MPN C125N360FM
Active

Schneider Electric ComPacT NS new generation, C125N360FM, 3P 1250 A circuit breaker with MicroLogic 6.0 electronic trip unit, 50 kA Icu at 415 V AC, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C125N360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C125N360FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C125N360FM is a 3-pole ComPacT NS new generation circuit breaker rated 1250 A at 50 °C, with a MicroLogic 6.0 electronic trip unit. This is a distribution breaker, not a motor-protection device — the LSI protection curve (long-time, short-time, instantaneous) is set for feeder or main switchboard duty. The MicroLogic 6.0 trip unit provides electronic overload (L), short-time short-circuit (S), and instantaneous (I) protection, with a 20-minute thermal memory that prevents nuisance reclosing after a thermal trip. Earth-leakage protection is not integrated — specify an external Vigi module if ground-fault detection is needed.

Physical integration and environment

Fixed-mount, backplate installation. Dimensions: 327 mm high, 210 mm wide, 147 mm deep. Connection pitch is 70 mm; both upside and downside connections are front-accessible. Power losses are 44 W at rated current — factor that into panel thermal calculations.

MPN
C125N360FM