Skip to main content
Schneider Electric C125N42AFM — Molded Case Circuit Breakers (MCCB)

C125N42AFM ComPacT NS 1250A 4P MCCB, MicroLogic 2.0, 50 kA 4

MPNC125N42AFM
Active

Schneider Electric ComPacT NS new generation, C125N42AFM, 1250 A at 50 °C, 4P, MicroLogic 2.0 A electronic trip unit, 50 kA Icu at 415 V AC, IP40.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C125N42AFM — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
C125N42AFM — Ratings
ParameterValue
Number of poles4P
C125N42AFM — Electrical
ParameterValue
[In] rated current1250 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
C125N42AFM — Specifications
ParameterValue
Trip unit nameMicroLogic 2.0 A
Trip unit technologyElectronic
StandardsEN/IEC 60947-2

Product details

The C125N42AFM is a fixed-mount ComPacT NS new generation MCCB from Schneider Electric, rated 1250 A at 50 °C with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection per EN/IEC 60947-2. The 4-pole configuration with neutral on the left handles three-phase distribution with a switched neutral. The IP40 enclosure keeps out tools and wires over 1 mm but not moisture, so mount it in a dry indoor panel or a weatherhead-rated enclosure.

Fixed-mount on a backplate (mounting support), with front-facing connections on both the line and load sides — no rear or plug-in base. Dimensions are 327 mm high, 280 mm wide, 147 mm deep, with a 70 mm connection pitch between phases. The LCD display on the front shows real-time current readings (ammeter measurement type), and four red LEDs signal fault types plus one yellow LED for overload. Pollution degree 3 (IEC 60947) means it tolerates conductive dust in industrial environments, but the IP40 rating still calls for a clean panel interior or an additional enclosure for washdown areas.

Frequently asked questions

How do I get current pricing and availability for C125N42AFM?

The C125N42AFM is sourced to order through independent distribution. Submit an RFQ — current pricing and availability are confirmed at quote time.

What is C125N42AFM's breaking capacity at 415 V AC?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That is the N breaking capacity code — sufficient for most industrial distribution panels at 400 V line voltage.

What compliance documentation does Schneider Electric provide for C125N42AFM?

The MCCB is certified to EN/IEC 60947-2, with IP40 per IEC 60529 and IK07 per EN 50102. Overvoltage category III and pollution degree 3 are listed. RoHS, REACH, and UL documentation are typically included in the manufacturer's compliance pack — request them with your RFQ.

MPN
C125N42AFM