Skip to main content
Schneider Electric C160H32AFM

C160H32AFM ComPacT NS 1600A MCCB, 70kA 415V, MicroLogic 2.0

MPN C160H32AFM
Active

Schneider Electric ComPacT NS new generation, C160H32AFM, 3P fixed MCCB, 1600 A, MicroLogic 2.0 A electronic trip unit, 70 kA at 415 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H32AFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160H32AFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C160H32AFM is a 3-pole fixed-mount ComPacT NS new generation MCCB rated 1600 A at 50 °C with a MicroLogic 2.0 A electronic trip unit. The 2.0 A trip provides L (long-time overload) and I (instantaneous short-circuit) protection — no ground-fault function on this variant.

The 1600 A continuous rating at 50 °C is the full-frame current; no derating needed at that ambient. The MicroLogic 2.0 A electronic trip unit measures true RMS current and provides a 20-minute thermal memory for accurate overload protection after a trip — important for motor or transformer feeders that see repeated start cycles. IP40 front-face protection means it's shielded against tools and small wires but not water — standard for indoor switchgear. The IK07 impact rating confirms it withstands a 2 J hammer blow to the enclosure face.

Fixed-mount design with backplate mounting support and a 70 mm connection pitch. Front-facing upper and lower connections simplify busbar and cable landing in a standard switchboard lineup. Dimensions are 327 mm high × 210 mm wide × 147 mm deep — fits a typical 600 mm wide cubicle with room for side-mounted auxiliaries. The LCD display on the MicroLogic trip unit shows real-time current and trip event data; the four red LEDs indicate fault type and one yellow LED signals overload pre-alarm.

MPN
C160H32AFM