Skip to main content
Schneider Electric C160N450FM

Schneider Electric C160N450FM ComPacT NS 1600A, 50kA 415V AC

MPN C160N450FM
Obsolete

Schneider Electric ComPacT NS new generation, C160N450FM, 4P fixed circuit breaker, 1600 A, MicroLogic 5.0 electronic trip unit, 50 kA Icu at 415 V AC, manually operated, front-connected.

$6,119.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160N450FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160N450FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C160N450FM is a fixed-mount, 4-pole ComPacT NS new generation circuit breaker rated 1600 A at 50 °C, built for AC distribution in switchboards and panelboards that require compliance with EN/IEC 60947-2. The 1600 A continuous rating governs the busbar and cable sizing upstream — this breaker does not derate at 50 °C, so the full 1600 A is available at that ambient. The MicroLogic 5.0 electronic trip unit provides LSI protection: long-time overload (L), short-time short-circuit (S) with adjustable time delay for selectivity, and instantaneous (I) for fault clearing. Utilisation category B means the breaker is suitable for distribution with no special current-limiting requirements upstream.

Mounts fixed to a backplate (mounting support: backplate). Front-connected on both upside and downside — all cable or busbar terminations are accessible from the front, which simplifies panel layout and gland-plate planning. Connection pitch is 70 mm, matching standard busbar spacing for 1600 A class breakers. Dimensions: 327 mm high, 280 mm wide, 147 mm deep — verify enclosure depth and door clearance before committing the cutout. IK07 impact protection (EN 50102) covers incidental mechanical shock during installation.

Selectivity and protection coordination

The MicroLogic 5.0 trip unit's LSI curves allow full selectivity with downstream breakers. The S (short-time) protection has adjustable time delay and I²t on/off — critical for cascading coordination in a distribution tree. Thermal memory of 20 minutes means the trip unit remembers the thermal state of the breaker after a trip, preventing immediate reclose on a hot conductor. Electrical durability: 1000 cycles at 690 V In, 2000 cycles at 690 V In/2, 2000 cycles at 440 V In, 5000 cycles at 440 V In/2. Mechanical durability: 10 000 cycles. Power losses are 74 W at rated current — factor this into enclosure ventilation calculations. No earth-leakage protection built in (without); if ground-fault protection is needed, specify a separate module or a MicroLogic 6.0/7.0 trip unit instead.

MPN
C160N450FM