Schneider Electric C16B44B160

Schneider C16B44B160 ComPacT NSX160B, 160A, 40kA at 240V

MPN C16B44B160
Active

Schneider Electric ComPacT NSX160B, 160A, 4P, 40kA Icu at 240V AC, MicroLogic 4.2 AB trip unit with integrated earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16B44B160 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C16B44B160 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationSpecial application
Operating temperature-25...70 °C

Product details

The Schneider C16B44B160 is a ComPacT NSX160B molded-case circuit breaker, 4-pole, rated 160 A at 40 °C. It carries a MicroLogic 4.2 AB electronic trip unit that combines overload (L), short-time short-circuit (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection in one package. The breaking capacity is 40 kA Icu at 220/240 V AC and 25 kA Icu at 380/415 V AC, per EN/IEC 60947-2.

Above that, the electronic trip curve derates automatically. The MicroLogic 4.2 AB is a fixed-setting unit — no field-adjustable long-time or short-time pickups — so the protection profile is set at the factory for the 160 A frame. The integrated earth-leakage (R) protection means you don't need a separate RCD module; the breaker itself detects ground faults and trips via the rotary IΔn switch. The 20-minute thermal memory before and after tripping means the breaker remembers a prior overload and shortens the cool-down period, which prevents nuisance re-closing on a still-hot conductor.

Front connection both upside and downside. The 140 mm width and 161 mm height fit standard ComPacT NSX panel cutouts. The IP40 front face keeps out tools and fingers; IK07 impact protection handles incidental knocks during panel assembly.

MPN
C16B44B160