Schneider Electric C16B44B160 — Residual Current Breakers (RCCB/RCBO)

Schneider C16B44B160 ComPacT NSX160B, 160A, 40kA at 240V

MPNC16B44B160
Obsolete

Schneider Electric ComPacT NSX160B, 160A, 4P, 40kA Icu at 240V AC, MicroLogic 4.2 AB trip unit with integrated earth-leakage protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16B44B160 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16B44B160 — Electrical Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16B44B160 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160B
C16B44B160 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16B44B160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16B44B160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider C16B44B160 is a ComPacT NSX160B molded-case circuit breaker, 4-pole, rated 160 A at 40 °C. It carries a MicroLogic 4.2 AB electronic trip unit that combines overload (L), short-time short-circuit (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection in one package. The breaking capacity is 40 kA Icu at 220/240 V AC and 25 kA Icu at 380/415 V AC, per EN/IEC 60947-2.

Above that, the electronic trip curve derates automatically. The MicroLogic 4.2 AB is a fixed-setting unit — no field-adjustable long-time or short-time pickups — so the protection profile is set at the factory for the 160 A frame. The integrated earth-leakage (R) protection means you don't need a separate RCD module; the breaker itself detects ground faults and trips via the rotary IΔn switch. The 20-minute thermal memory before and after tripping means the breaker remembers a prior overload and shortens the cool-down period, which prevents nuisance re-closing on a still-hot conductor.

Front connection both upside and downside. The 140 mm width and 161 mm height fit standard ComPacT NSX panel cutouts. The IP40 front face keeps out tools and fingers; IK07 impact protection handles incidental knocks during panel assembly.

Frequently asked questions

Where can I buy C16B44B160?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is C16B44B160's breaking capacity at 415 V?

25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. This is the code B rating that governs most European industrial panel designs.

What protection functions does the MicroLogic 4.2 AB trip unit provide?

It provides overload (L), short-time short-circuit with fixed delay (So), instantaneous short-circuit (I), and integrated earth-leakage (R) protection.

Does C16B44B160 include earth-leakage protection?

Yes, earth-leakage protection is integrated into the MicroLogic 4.2 AB trip unit. No separate RCD module is required.

MPN
C16B44B160