Skip to main content
Schneider Electric C16B44V100

Schneider Electric C16B44V100 ComPacT NSX160B, 100 A, 4P, Mi

MPN C16B44V100
Active

Schneider Electric ComPacT NSX160B, 4P, 100 A at 40 °C, MicroLogic 4.2 electronic trip unit, 40 kA Icu at 240 V AC, EN/IEC 60947-2.

$649.57 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16B44V100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C16B44V100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this NSX160B carries

The C16B44V100 is a Schneider Electric ComPacT NSX160B moulded-case circuit breaker, 4-pole (4P), rated 100 A at 40 °C. It uses a MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection — L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage). Breaking capacity hits 40 kA Icu at 240 V AC, 25 kA at 415 V, 20 kA at 440 V, and 15 kA at 500 V, all per IEC 60947-2.

Fit and mounting

Front connections top and bottom, neutral on the left. IP40 enclosure protection, IK07 impact rating. Five accessory slots, 35 mm connection pitch. Panel builders: the 86 mm depth and front wiring keep it manageable in a standard distribution board.

Current-production part — no end-of-life notice on record.

Category A utilisation means it's not intended for current-limiting duty in high-fault systems.

MPN
C16B44V100