Skip to main content
Schneider Electric C16B47E160 — Residual Current Breakers (RCCB/RCBO)

Schneider C16B47E160 ComPacT NSX 4-pole 160 A MCCB, 40 kA

MPNC16B47E160
Active

Schneider C16B47E160 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.

$1,140.13 – $1,642.73Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026

Specifications

C16B47E160 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16B47E160 — Electrical Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16B47E160 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160B
C16B47E160 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16B47E160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16B47E160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Overview

The C16B47E160 is a 4-pole ComPacT NSX molded case circuit breaker rated 160 A at 40 °C, fitted with a MicroLogic 7.2 E electronic trip unit that provides overload (L), short-time (S), instantaneous (I), and earth-leakage (R) protection on a 440 V AC network. Its 40 kA breaking capacity (Icu) at 440 V AC suits distribution panels where fault levels reach that threshold; the 4-pole design with neutral on the left handles three-phase plus neutral circuits without an additional neutral disconnect.

The C16B47E160 carries 4 poles and a 160 A frame; the 3-pole C16B3 is rated 15 kA at 690 V AC and lacks the earth-leakage trip unit, so the C16B47E160 is the correct choice when a 4-pole, 160 A, earth-leakage-protected breaker is specified.

MPN
C16B47E160