Schneider Electric C16F34V100 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C16F34V100 ComPacT NSX 100A 3P Earth Leak

MPNC16F34V100
Active

Schneider Electric ComPacT NSX, NSX160F, earth leakage circuit breaker, 3P, 100 A at 40 °C, MicroLogic 4.2 trip unit, 85 kA Icu at 240 V AC.

$1,080.58 – $2,165.94Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16F34V100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16F34V100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16F34V100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160F
C16F34V100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16F34V100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16F34V100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C16F34V100 is a ComPacT NSX160F earth leakage circuit breaker (ELCB) with a MicroLogic 4.2 electronic trip unit, rated 100 A at 40 °C. It's a 3-pole unit built for distribution applications, integrating overload, short-circuit, and earth-leakage protection in one frame.

At 480 V AC it still holds 35 kA Icu per UL 60947-4-1.

Listed as current production (lifecycle stage: current). No phase-out or last-time-buy notice on record. Standard catalog item in the ComPacT NSX family.

IP40 enclosure protection, IK07 impact resistance.

Electrical durability: 40,000 cycles at 440 V In/2, 20,000 cycles at 440 V In. Mechanical durability: 40,000 cycles. Utilisation category A (non-delayed). Relative humidity 0–95 %.

Frequently asked questions

What are the key ratings for C16F34V100?

The C16F34V100 is a 3-pole earth leakage circuit breaker rated 100 A at 40 °C with a MicroLogic 4.2 electronic trip unit. Breaking capacity is 85 kA Icu at 240 V AC and 36 kA Icu at 415 V AC per IEC 60947-2.

What compliance documentation does this brand provide for C16F34V100?

The C16F34V100 is certified to EN/IEC 60947-2 and UL 60947-4-1 standards. It carries IP40 and IK07 protection ratings, pollution degree 3 per IEC 60664-1, and overvoltage category IV.

MPN
C16F34V100