Schneider Electric C16F44V100

Schneider Electric C16F44V100 ComPacT NSX160F, 100 A, 36 kA

MPN C16F44V100
Active

Schneider Electric ComPacT NSX160F, 100 A, 4P, MicroLogic 4.2 electronic trip unit, 36 kA Icu at 415 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16F44V100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C16F44V100 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C16F44V100 is a ComPacT NSX160F moulded-case circuit breaker (MCCB) with a 100 A MicroLogic 4.2 electronic trip unit, four poles, and an F breaking capacity rating of 36 kA Icu at 415 V AC. It is designed for distribution applications and carries integrated earth-leakage protection, making it a single-device solution for overload, short-circuit, and ground-fault protection in a 50/60 Hz network.

For higher fault levels at 240 V, it handles 85 kA Icu, so it coordinates well with a transformer secondary or a large motor branch. The MicroLogic 4.2 electronic trip unit provides L (long-time), So (short-time with fixed delay), I (instantaneous), and R (earth-leakage) protection curves; the 20-minute thermal memory before and after tripping prevents nuisance reclosure on a hot conductor.

Deployment and integration

Mounts on a backplate in horizontal or vertical orientation — flat-on-back only, no DIN-rail snap-on. The toggle control and the IΔn rotary switch for earth-leakage OFF are panel-face accessible.

MPN
C16F44V100