Skip to main content
Schneider Electric C16F44V160 — Residual Current Breakers (RCCB/RCBO)

Schneider C16F44V160 ComPacT NSX160F MCCB, 160 A, 85 kA

MPNC16F44V160
Active

Schneider Electric ComPacT NSX160F, 4P MCCB, 160 A at 40 °C, 85 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection, EN/IEC 60947-2.

$2,527.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16F44V160 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16F44V160 — Electrical Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16F44V160 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160F
C16F44V160 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16F44V160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16F44V160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Schneider Electric C16F44V160 is a ComPacT NSX160F 4-pole MCCB rated 160 A at 40 °C with a MicroLogic 4.2 electronic trip unit. The trip unit provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and integrated R (earth-leakage) protection. At 415 V AC it still holds 36 kA Icu, enough for most industrial distribution boards.

Built for the pit — mounting and environment

Mounts on a backplate in horizontal or vertical orientation. IK07 impact rating shrugs off a 2 J hammer blow during installation. Operating altitude to 2000 m without derating, up to 5000 m with derating. The 86 mm depth and 140 mm width fit standard distribution board cutouts.

Frequently asked questions

Where can I buy C16F44V160 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What is the breaking capacity of C16F44V160 at different voltages?

85 kA Icu at 220/240 V AC, 36 kA at 380/415 V AC, 35 kA at 440 V, 30 kA at 500 V, 22 kA at 525 V, and 8 kA at 660/690 V AC, all per IEC 60947-2. Also rated 85 kA at 240 V, 35 kA at 480 V, and 10 kA at 600 V per UL 60947-4-1.

What compliance documentation does this brand provide for C16F44V160?

The part is certified to EN/IEC 60947-2 and UL 60947-4-1. Pollution degree 3 per IEC 60664-1. IP40 per IEC 60529, IK07 per IEC 62262. Standard documentation includes the nameplate ratings, test certificates, and the full ComPacT NSX family manual.

What is the closest alternative to C16F44V160 in the ComPacT NSX family?

Within the same frame size (NSX160F), the closest alternative would be a variant with a different trip unit or accessory configuration — for example, a MicroLogic 2.3 instead of 4.2 (no earth-leakage), or a different breaking capacity code. Pin compatibility depends on the mounting base and busbar system; the 4P 160 A frame is shared across the NSX160 range.

MPN
C16F44V160