C16N42D100 ComPacT NSX Circuit Breaker, 100 A, 90 kA

MPN C16N42D100
Active

Schneider Electric ComPacT NSX circuit breaker, 100 A, 90 kA Icu at 240 V AC, MicroLogic 2.2 electronic trip unit, 4 poles, EN/IEC 60947-2.

$522.15 – $1,292.22 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16N42D100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C16N42D100 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C16N42D100 is a Schneider Electric ComPacT NSX circuit breaker, 4-pole, rated 100 A at 40 °C with a MicroLogic 2.2 electronic trip unit. It carries a 90 kA Icu breaking capacity at 240 V AC and 50 kA at 415 V AC, per EN/IEC 60947-2. The N breaking capacity code (50 kA at 415 V AC) tells you this is the standard-interrupting version of the NSX160N frame — sized for distribution panels where fault levels sit in that range, not the high-fault H or L versions.

The MicroLogic 2.2 electronic trip unit gives you L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous) protection curves. That So function with fixed delay is key for selective coordination downstream: you can set the short-time pickup and let a fault clear closer to the load before this breaker opens, keeping upstream feeders alive.

The 140 mm width, 161 mm height, and 86 mm depth fit standard distribution panel footprints. Front connections top and bottom; neutral on the left. IP40 enclosure protection (IK07 impact resistance) means it's suited for indoor panel installation where tools and accidental contact are the main concern, not washdown. The 35 mm connection pitch matches standard busbar and cable lug spacing.

Durability and duty

Mechanical durability is 40,000 cycles; electrical durability varies by load — 40,000 cycles at 440 V at half rated current, 20,000 at full 100 A, and 7,500 at 690 V. That's a solid service life for a distribution breaker in a panel that sees regular switching, not daily operation.