Schneider Electric C16N47E100 — Residual Current Breakers (RCCB/RCBO)

C16N47E100 ComPacT NSX 160N, MicroLogic 7.2 E, 100 A, 90 kA

MPNC16N47E100
Obsolete

Schneider Electric ComPacT NSX series, C16N47E100, NSX160N frame, 4P, 100 A, MicroLogic 7.2 E electronic trip unit, 90 kA Icu at 240 V AC.

$1,683.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N47E100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C16N47E100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (operating cycles)40000 cycles
C16N47E100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX160N
C16N47E100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C16N47E100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C16N47E100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C16N47E100 is a Schneider ComPacT NSX160N molded case circuit breaker with a MicroLogic 7.2 E electronic trip unit, rated 100 A at 40 °C. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage) protection — a full four-function package for distribution and feeder protection in a single device. The 90 kA Icu at 240 V AC (50/60 Hz) per IEC 60947-2 means it can safely interrupt a fault current up to that level without failing, which sets the SCCR for the downstream panel. At 480 V AC the interrupting rating is 50 kA Icu, still substantial for most industrial distribution boards.

The N breaking capacity code (50 kA at 415 V AC) is the standard industrial grade in the ComPacT NSX family — above the S (25 kA) but below the H (70 kA) and L (150 kA) grades. The 90 kA at 240 V AC gives headroom for low-voltage transformer secondaries. The MicroLogic 7.2 E adds energy metering and communication (time-stamped histories, demand values, power quality data) — this is the trip unit that turns a breaker into a panel-level power monitor, not just a protection device.

Mounting and integration — backplate, front connections, 35 mm pitch

The toggle control with LCD display gives local status and settings visibility.

Electrical and mechanical durability — cycles that define service life

Mechanical durability is 40,000 cycles — the number of open-close operations the mechanism can perform without maintenance. Electrical durability varies with load: 40,000 cycles at 440 V at half rated current (In/2), 20,000 cycles at 440 V at full In, and 7,500 cycles at 690 V at full In. For a feeder breaker that operates infrequently (a few times per year for maintenance switching), this is effectively a lifetime rating. For a breaker used as a disconnect in a frequent-start application, the 20,000-cycle figure at rated current sets the replacement interval.

Frequently asked questions

What is the breaking capacity of C16N47E100 at 480 V?

50 kA Icu at 480 V AC per UL 60947-4-1, and 50 kA Icu at 440 V AC per IEC 60947-2. At 240 V AC it is 90 kA Icu.

What protection functions does the MicroLogic 7.2 E trip unit provide?

L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage) protection. It also includes energy metering and communication features.

Where can I buy C16N47E100 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does C16N47E100 comply with?

EN/IEC 60947-2 for the IEC rating, and UL 60947-4-1 for the UL listing. Pollution degree 3 per IEC 60664-1.