Schneider Electric C16N4TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C16N4TM080 ComPacT NSX160N, 80 A Thermal-

MPNC16N4TM080
Active

Schneider Electric ComPacT NSX series, C16N4TM080, 4-pole circuit breaker with TM-D thermal-magnetic trip unit rated 80 A at 40 °C, breaking capacity 50 kA Icu at 415 V AC, IP40 enclosure protection.

$441.37Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N4TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16N4TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16N4TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16N4TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16N4TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16N4TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16N4TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 4-pole configuration (4P) with neutral left position suits distribution panels where full phase and neutral protection is required. That is an N-frame rating (50 kA at 415 V), which puts it in the middle of the NSX160 family — enough for most industrial distribution boards fed by a 1 MVA transformer, but not for high-fault substations where you would step up to an S or H frame. At 480 V AC the UL rating is also 50 kA Icu, so it crosses over cleanly into North American installations. The TM-D trip unit is fixed thermal-magnetic — no electronic adjustment, no interchangeable rating plugs. That means the 80 A setting is permanent; if you need a different amp rating later, you swap the whole breaker, not just the trip unit. For a fixed-load distribution board this is fine; for a panel that may be retasked, consider the electronic Micrologic version.

Front connections top and bottom simplify busbar and cable routing in a standard distribution panel. IP40 enclosure protection means it is suited for clean indoor panels — not for washdown or outdoor cabinets without an additional enclosure.

Frequently asked questions

Where can I buy C16N4TM080 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

What is the breaking capacity of C16N4TM080 at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2. At 480 V AC the UL rating is also 50 kA Icu.

What standards does C16N4TM080 comply with?

It complies with EN/IEC 60947-2 and UL 60947-4-1. It is suitable for isolation per EN/IEC 60947-2. Pollution degree 3 per IEC 60664-1.