Skip to main content
Schneider Electric C16N4TM100 — Miniature Circuit Breakers (MCB)

Schneider Electric C16N4TM100 ComPacT NSX 100A MCCB, 50 kA a

MPNC16N4TM100
Active

Schneider Electric ComPacT NSX, MCCB, 100 A, TM-D trip, 4P, 50 kA Icu at 415 V AC, IEC 60947-2.

$534.80 – $929.18Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N4TM100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16N4TM100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16N4TM100 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16N4TM100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16N4TM100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16N4TM100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16N4TM100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C16N4TM100 is a ComPacT NSX moulded-case circuit breaker rated 100 A at 40 °C with a TM-D thermal-magnetic trip unit. It carries a 50 kA Icu breaking capacity at 415 V AC (IEC 60947-2), which means it can safely interrupt a fault up to that level without upstream damage — sized for distribution panels where the available fault current is known and the breaker clears it. The 4P configuration with neutral left and front-connect terminals suits standard backplate mounting in switchboards and motor control centres.

The N-frame breaking capacity code gives 50 kA Icu at 380/415 V AC — the dominant rating for 400 V-class distribution in IEC territories. At 240 V AC it jumps to 90 kA Icu; at 690 V AC it drops to 10 kA Icu. The so-what: if your facility's transformer or upstream gear can deliver a fault current above 50 kA at 415 V, this breaker won't hold — step to an S-frame or H-frame NSX.

The 140 mm width and 161 mm height fit standard switchboard cubicle cutouts; 86 mm depth leaves headroom for rear cable entry. IP40 enclosure protection keeps dust out but is not rated for washdown — install inside a cabinet.

Designed and tested to EN/IEC 60947-2, with overvoltage category III and pollution degree 3 per IEC 60664-1 — suitable for fixed-installation industrial panels. The breaker is marked as suitable for isolation (EN/IEC 60947-2), meaning it can be used as a visible-break disconnect when locked off. IK07 impact resistance and IP40 ingress protection cover normal handling and indoor panel environments.

Frequently asked questions

What is the breaking capacity of C16N4TM100?

50 kA Icu at 380/415 V AC and 90 kA Icu at 220/240 V AC, both conforming to IEC 60947-2.

Where can I buy C16N4TM100?

It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance standards does C16N4TM100 meet?

It is certified to EN/IEC 60947-2, with overvoltage category III, pollution degree 3, and suitability for isolation per the same standard.

MPN