Schneider Electric C2534V250 — Residual Current Breakers (RCCB/RCBO)

Schneider C2534V250 ComPacT NSX MicroLogic 4.2 Trip Unit, 25

MPNC2534V250
Active

Schneider Electric, ComPacT NSX100...250, MicroLogic 4.2 electronic trip unit, 250 A at 40 °C, 3P 3D, integrated earth-leakage Class A, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C2534V250 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload Color indicator (yellow) for residual current
C2534V250 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C2534V250 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C2534V250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C2534V250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C2534V250 is a MicroLogic 4.2 electronic trip unit for the ComPacT NSX100...250 molded-case circuit breaker platform. It's rated 250 A at 40 °C, 3-pole, 3 protected poles (3D), with integrated earth-leakage protection Class A. That standard covers the breaking and switching performance for low-voltage switchgear — so this unit is certified for the fault-clearing and coordination duties a panel designer expects from a distribution breaker.

Mounts fixed in a ComPacT NSX250 frame. IP40 front face (finger-safe behind the door), pollution degree 3 per IEC 60947-1 — fine for a standard industrial panel environment. The 20-minute thermal memory before and after tripping means the unit remembers the heat history of the conductor; if you clear a fault and re-energize quickly, the trip curve accounts for the residual heat, so nuisance trips on a hot reclose are less likely.

Protection functions are LSoIR: long-time overload (L), short-time short-circuit with fixed delay (So), instantaneous short-circuit (I), and residual/earth-leakage (R). The long-time pickup Ir is adjustable 100–250 A across 9 settings — that's the thermal-magnetic curve's continuous-current threshold. Short-time pickup Isd adjusts 1.5–10 x Ir; instantaneous Ii is fixed at 3000 A. Earth-leakage sensitivity IΔn is adjustable, with time delays Δt selectable from 0 ms to 1 s (0, 60, 150, 500 ms, 1 s). The unit can be switched OFF via the IΔn rotary switch if the installation doesn't require ground-fault protection. Local signaling includes a flashing green LED for ready, red LED at 105% Ir for overload, orange at 90% Ir, and a yellow indicator for residual current.

Frequently asked questions

What standards does C2534V250 comply with?

It complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear.

What is the closest alternative to C2534V250 in the ComPacT family?

Within the ComPacT NSX250 platform, the closest sibling is a MicroLogic 4.2 unit with the same 250 A rating but without integrated earth-leakage (the 4.2 version without the R function). The deciding factor is whether the installation requires residual-current protection built into the trip unit, or if it's handled externally by a separate RCD or relay.

Where can I buy C2534V250 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
C2534V250