Schneider Electric C25B32D250 — Miniature Circuit Breakers (MCB)

Schneider Electric C25B32D250 ComPacT NSX250B, 250 A, 40 kA

MPNC25B32D250
Active

Schneider Electric ComPacT NSX circuit breaker, NSX250B frame, 250 A, 40 kA Icu at 240 V AC, MicroLogic 2.2 electronic trip unit, 3-pole.

$441.92Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C25B32D250 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25B32D250 — Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Poles configuration3P
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25B32D250 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25B32D250 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25B32D250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25B32D250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25B32D250 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range100...250 A
Trip unit protection functionsLSoI

Product details

The C25B32D250 is a Schneider Electric ComPacT NSX250B moulded-case circuit breaker (MCCB) in the ComPacT range, rated 250 A at 40 °C with a MicroLogic 2.2 electronic trip unit. The MicroLogic 2.2 provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection curves, so you can coordinate selectively downstream without nuisance tripping on motor inrush or transformer energisation. Breaking capacity is 40 kA Icu at 220/240 V AC, 25 kA at 380/415 V, 20 kA at 440 V, and 15 kA at 500 V, all per IEC 60947-2. The 3-pole (3P) version covers three-phase distribution.

Selectivity and coordination

This allows cascaded selectivity with downstream breakers — a 250 A feeder can hold in for a downstream 100 A branch fault long enough for the branch breaker to clear, keeping the rest of the panel live. Utilisation category A means it is not intended for frequent switching of motor loads under normal operation — it is a distribution breaker, not a motor starter. For motor circuit protection, pair it with a contactor and overload relay upstream.

Connection pitch is 35 mm, so busbar or cable lugs align with standard 35 mm centres. IP40 enclosure protection is fine for clean indoor panels; IK07 impact resistance handles accidental tool drops during maintenance. Mounts horizontally or vertically flat on the backplate — no derating needed for orientation.

Frequently asked questions

What is the breaking capacity of C25B32D250 at 415 V?

25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 440 V it drops to 20 kA, and at 500 V to 15 kA.

What trip unit does C25B32D250 use?

A MicroLogic 2.2 electronic trip unit with L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection.