Schneider Electric C25H3MA220

Schneider Electric C25H3MA220 ComPacT NSX 250H, 220A MA Trip

MPN C25H3MA220
Active

Schneider Electric ComPacT NSX, NSX250H, MCCB, 3P, 220 A, MA magnetic trip unit, 70 kA Icu at 415 V AC, motor protection.

$485.07 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25H3MA220 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C25H3MA220 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The MA trip unit is magnetic-only — no thermal element — so it provides short-circuit protection (I) only, leaving overload protection to an external relay or motor starter. That's standard for motor feeders where the contactor and overload handle running protection and the MCCB is there for the hard fault. The 220 A rating at 65 °C means the trip unit is calibrated for continuous current at that ambient; in a 50 °C cement plant control room you have headroom, but if the panel sits near the kiln at 65 °C you're right at the limit. Breaking capacity varies with voltage: 100 kA at 240 V, 70 kA at 415 V, 65 kA at 440 V, down to 10 kA at 690 V. For a 415 V motor feeder that 70 kA Icu gives solid selectivity with upstream gear — you can coordinate without oversizing the whole lineup. The 3-pole, 3-protected-pole configuration (3D) means all three poles have trip protection, not just a switched neutral. IP40 enclosure protection keeps out tools and fingers but not dust — this is a panel-mounted breaker, not a standalone enclosure. Mount it on a backplate (flat, horizontal or vertical) inside a cabinet that handles the dust seal.