Schneider Electric C25H42D250 — Miniature Circuit Breakers (MCB)

Schneider C25H42D250 ComPacT NSX250H, 250 A, 4P, 100 kA

MPNC25H42D250
Active

Schneider Electric ComPacT NSX250H, C25H42D250, 4P circuit breaker, 250 A at 40 °C, MicroLogic 2.2 electronic trip unit, 100 kA Icu at 240 V AC, EN/IEC 60947-2.

$732.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C25H42D250 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25H42D250 — Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Poles configuration4P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25H42D250 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25H42D250 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25H42D250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25H42D250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25H42D250 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range100...250 A
Trip unit protection functionsLSoI

Product details

The C25H42D250 is a Schneider Electric ComPacT NSX250H molded-case circuit breaker with a MicroLogic 2.2 electronic trip unit, rated 250 A at 40 °C across 4 poles. The H breaking capacity code delivers 100 kA Icu at 220/240 V AC and 70 kA Icu at 380/415 V AC, both per IEC 60947-2 — that headroom means it clears high-fault currents on a distribution bus without upstream coordination issues.

Mounts on a backplate in either horizontal or vertical orientation, flat on the back — no DIN-rail clip, so plan for bolted panel mounting. Front connections on both the upside and downside simplify bus-bar or cable routing in a distribution panel. The 4-pole layout with neutral on the left fits standard switchboard phase arrangements. IP40 front face and IK07 impact resistance are adequate for enclosed panel environments; keep the enclosure door closed during operation.

Durability and environment

Rated for 20,000 mechanical cycles and up to 20,000 electrical cycles at 440 V at half-rated current (10,000 at full rated current). The thermal memory holds the trip profile for 20 minutes before and after a trip event, so re-energizing a hot breaker doesn't nuisance-trip on a second overload.

Frequently asked questions

How do I get current pricing and availability for C25H42D250?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the breaking capacity of C25H42D250 at 415 V?

The C25H42D250 delivers 70 kA Icu at 380/415 V AC per IEC 60947-2, matching the H breaking capacity code.

What trip unit does the C25H42D250 use?

It uses a MicroLogic 2.2 electronic trip unit with L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection.

What compliance documentation does Schneider provide for C25H42D250?

The breaker is certified to EN/IEC 60947-2 and carries UL 60947-4-1 ratings. Pollution degree 3 per IEC 60664-1 and IK07 per IEC 62262 are documented.

MPN