Schneider Electric C25N34V250 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C25N34V250 ComPacT NSX Earth Leakage Circ

MPNC25N34V250
Active

Schneider Electric ComPacT NSX, earth leakage circuit breaker, 3P, 250 A at 40 °C, 90 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit, IP40, toggle control.

$1,210.66 – $3,480.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25N34V250 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25N34V250 — Electrical Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C25N34V250 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX250N
C25N34V250 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C25N34V250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C25N34V250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C25N34V250 is a ComPacT NSX earth leakage circuit breaker with a MicroLogic 4.2 electronic trip unit rated 250 A at 40 °C. Breaking capacity hits 90 kA Icu at 240 V AC and 50 kA at 415 V AC per IEC 60947-2. The integrated earth-leakage protection uses an IΔn rotary switch for OFF mode, with a 20-minute thermal memory before and after tripping. That thermal memory means the breaker remembers the heat profile of a sustained overload — useful on motor or transformer feeders where the same load cycles back on quickly.

Lifecycle status is current per the manufacturer.

Mounts on a backplate, accepts horizontal or vertical orientation flat against the panel. Width is 105 mm, height 161 mm, depth 86 mm — fits standard panel cutouts for 3-pole molded-case breakers. IP40 enclosure, IK07 impact resistance. Five accessory slots available for shunt trips, auxiliary contacts, or communication modules.

Protection and ratings

Electronic trip unit eliminates thermal drift issues of bimetal types. Electrical durability: 20,000 cycles at 440 V In/2, 10,000 cycles at 440 V In. Mechanical durability 20,000 cycles. Category A utilization. IEC 60947-2 compliance covers the breaking capacities across the voltage range. Local signaling via green flashing LED for ready, red LED at 105% Ir for overload, orange at 90% Ir.

Frequently asked questions

Where can I buy C25N34V250 and how do I get a price?

The C25N34V250 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit a request for quote.

What are the key ratings for C25N34V250?

Trip unit rating is 250 A at 40 °C. Breaking capacity is 90 kA Icu at 240 V AC, 50 kA at 415 V AC per IEC 60947-2. Earth-leakage protection is integrated. The trip unit is MicroLogic 4.2 electronic.

MPN