Skip to main content
Schneider Electric C25R36M150 — Residual Current Breakers (RCCB/RCBO)

Schneider C25R36M150 ComPacT NSX 150A MCCB, 200kA 415V

MPNC25R36M150
Obsolete

Schneider Electric ComPacT NSX, NSX250R, MCCB, 3P, 150 A, MicroLogic 6.2 E-M electronic trip unit, 200 kA Icu at 415 V AC, motor protection.

$20.55Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25R36M150 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C25R36M150 — Electrical Ratings
ParameterValue
Rated current (In)150 A at 65 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C25R36M150 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX250R
C25R36M150 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C25R36M150 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C25R36M150 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C25R36M150 is a ComPacT NSX250R MCCB with a MicroLogic 6.2 E-M electronic trip unit, rated 150 A at 65 °C. It provides motor protection with L, So, I, and G protection and selectable tripping classes 5, 10, 20, and 30. The electronic trip unit includes an LCD display for energy metering, demand values, power quality data, and time-stamped event logs — useful for tracking motor starts and fault history on a pump or compressor circuit.

IK07 impact resistance (IEC 62262) means the enclosure withstands 2 J impacts — adequate for general industrial panel environments where tools or dropped parts are a risk. The toggle control and flashing green/red LED give local status without opening the panel door.

Frequently asked questions

What compliance documentation does Schneider provide for C25R36M150?

The MCCB is certified to EN/IEC 60947-2. The evidence does not list RoHS, REACH, or UL documentation — these are typically available in the product's compliance declaration from Schneider Electric upon request.

MPN