Schneider Electric C25S4 — Molded Case Circuit Breakers (MCCB)

C25S4 ComPacT NSX250S Basic Frame, 250A, 100kA/415VAC, 4P

MPNC25S4
Active

Schneider Electric ComPacT NSX250S basic frame, C25S4, 250 A frame rating, 100 kA Icu at 415 V AC, 4 poles, without trip unit.

$569.47 – $1,485.82Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C25S4 — Identification
ParameterValue
Product / component typeBasic frame
Device applicationDistribution
C25S4 — Electrical
ParameterValue
[In] rated current250 A at 40 °C
Breaking capacity100 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 120 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 90 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity100 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 120 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 90 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
C25S4 — Specifications
ParameterValue
Poles description4P
Device short nameNSX250S
StandardsEN/IEC 60947-2 UL 60947-4-1

Product details

The C25S4 is a ComPacT NSX250S basic frame — a 250 A moulded-case frame rated for distribution duty, built to EN/IEC 60947-2 and UL 60947-4-1. It ships without a trip unit, so you pair it with a separate electronic or thermal-magnetic trip module to set the actual protection curve. That is an S-break capacity class, typical for high-fault industrial switchboards where the available fault current exceeds 65 kA. The 690 V AC rated operational voltage and 800 V AC rated insulation voltage confirm it handles 480/600 V systems with margin, and the 8 kV impulse withstand covers surge environments typical of overvoltage category III and pollution degree 3.

Deployment context

This is a fixed-mount frame for backplate mounting — it bolts into a switchboard or panel enclosure, not a DIN rail. The 140 mm width and 161 mm height with 86 mm depth and a 35 mm connection pitch define the cutout and bus-bar spacing. The toggle control provides manual on/off and trip indication. Front-face Class II shock protection means no additional grounding of the front cover is required for operator safety.

Frequently asked questions

What is C25S4's breaking capacity at 415 V AC?

The C25S4 has a 100 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2. The service breaking capacity Ics at the same voltage is also 100 kA, meaning it can be reclosed after a fault at that level without immediate replacement.

What trip unit does the C25S4 require?

The C25S4 is a basic frame without a trip unit. You select a separate electronic or thermal-magnetic trip module from the ComPacT NSX family to set the protection curve (e.g., Micrologic 2.0, 5.0, or 6.0 series).

Where can I buy the C25S4?

The C25S4 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN