Skip to main content
Schneider Electric C4036M320 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C4036M320 MicroLogic 6.3 E-M Trip Unit, 3

MPNC4036M320
Obsolete

Schneider Electric ComPacT NSX series, MicroLogic 6.3 E-M electronic trip unit, 320 A at 65 °C, LSIG protection, for motor applications, 3P, IEC 60947-2.

$475.58 – $504.11Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C4036M320 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C4036M320 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C4036M320 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C4036M320 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C4036M320 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

What this trip unit does and why it matters

The C4036M320 is a MicroLogic 6.3 E-M electronic trip unit for the ComPacT NSX400...630 molded-case circuit breaker family. It's rated 320 A at 65 °C and provides LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — specifically tuned for motor loads. The E-M designation means it includes complementary motor protection functions like protracted starting time, current unbalance, underload, and stalled rotor protection, with selectable trip classes 5, 10, 20, or 30. That trip class selection lets you match the thermal curve to the motor's starting profile — a pump with a long start-up time needs class 20 or 30 to avoid nuisance tripping during acceleration.

Protection and metering in one unit

This trip unit isn't just a protective relay — it's also an energy meter. The LCD display shows instantaneous and demand values, power quality data, and time-stamped event logs. Zone selective interlocking (ZSI) is built in, which lets multiple breakers in a cascade coordinate their short-time trip delays — the breaker closest to the fault clears first, while upstream breakers hold off, keeping the rest of the line live.

The trip unit snaps into a fixed-mount ComPacT NSX breaker. The breaker itself occupies a standard DIN-rail footprint, though the NSX frame is bolted, not DIN-clipped. The IP40 front-of-panel protection means it's fine for a clean indoor enclosure, but keep it away from washdown zones. The 3D protected poles description means all three poles are monitored for ground fault, not just one.

Frequently asked questions

What is C4036M320's listed range and standards?

It belongs to the ComPacT NSX400...630 range and complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear.

What protection functions does the MicroLogic 6.3 E-M provide?

LSIG: long-time overload (L), short-time short-circuit with fixed delay (S), instantaneous short-circuit (I), and ground-fault (G). It also adds motor-specific protections like stalled rotor, current unbalance, and underload.

Where can I buy C4036M320 and how is it quoted?

This trip unit is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing.

MPN
C4036M320