Skip to main content
Schneider Electric C4036M320

Schneider Electric C4036M320 MicroLogic 6.3 E-M Trip Unit, 3

MPN C4036M320
Active

Schneider Electric ComPacT NSX series, MicroLogic 6.3 E-M electronic trip unit, 320 A at 65 °C, LSIG protection, for motor applications, 3P, IEC 60947-2.

$475.58 – $504.11 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C4036M320 specifications
ParameterValue
Display typeLCD display
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage690 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationMotor
Operating temperature-25...70 °C

Product details

What this trip unit does and why it matters

The C4036M320 is a MicroLogic 6.3 E-M electronic trip unit for the ComPacT NSX400...630 molded-case circuit breaker family. It's rated 320 A at 65 °C and provides LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — specifically tuned for motor loads. The E-M designation means it includes complementary motor protection functions like protracted starting time, current unbalance, underload, and stalled rotor protection, with selectable trip classes 5, 10, 20, or 30. That trip class selection lets you match the thermal curve to the motor's starting profile — a pump with a long start-up time needs class 20 or 30 to avoid nuisance tripping during acceleration.

Protection and metering in one unit

This trip unit isn't just a protective relay — it's also an energy meter. The LCD display shows instantaneous and demand values, power quality data, and time-stamped event logs. Zone selective interlocking (ZSI) is built in, which lets multiple breakers in a cascade coordinate their short-time trip delays — the breaker closest to the fault clears first, while upstream breakers hold off, keeping the rest of the line live.

The trip unit snaps into a fixed-mount ComPacT NSX breaker. The breaker itself occupies a standard DIN-rail footprint, though the NSX frame is bolted, not DIN-clipped. The IP40 front-of-panel protection means it's fine for a clean indoor enclosure, but keep it away from washdown zones. The 3D protected poles description means all three poles are monitored for ground fault, not just one.

MPN
C4036M320