Skip to main content
Schneider Electric C40N37E400 — Residual Current Breakers (RCCB/RCBO)

Schneider C40N37E400 ComPacT NSX earth-leakage breaker, 400 A, 85 kA

MPNC40N37E400
Obsolete

Schneider C40N37E400 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.

$2,362.93Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C40N37E400 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C40N37E400 — Electrical Ratings
ParameterValue
Rated current (In)400 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C40N37E400 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX400N
C40N37E400 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C40N37E400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C40N37E400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Overview

The C40N37E400 is a Schneider ComPacT NSX earth-leakage circuit breaker rated 400 A continuous with an 85 kA ICu breaking capacity at 440 V AC, fitted with a MicroLogic 7.3 E electronic trip unit that provides L, S, I, and R protection profiles.

The C40N37E400 shares the same 400 A frame and 85 kA ICu as the C40F3, but the C40F3 is a basic-frame breaker without earth-leakage protection — the C40N37E400 adds the MicroLogic 7.3 E trip unit with R (earth-leakage) protection. Both are 3-pole, fixed-mount, and rated 440 V AC / 500 V insulation, so the C40N37E400 drops into a panel wired for the C40F3 without rewiring, provided the earth-leakage function is required.

MPN
C40N37E400