Schneider Electric C40R46E400 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C40R46E400 ComPacT NSX 400A, 200kA Breake

MPNC40R46E400
Obsolete

Schneider Electric ComPacT NSX series, NSX400R molded case circuit breaker, 400 A, 200 kA Icu at 415 V AC, 4-pole, MicroLogic 6.3 E electronic trip unit.

$41.25Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C40R46E400 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C40R46E400 — Electrical Ratings
ParameterValue
Rated current (In)400 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C40R46E400 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX400R
C40R46E400 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C40R46E400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C40R46E400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

What this 400 A MCCB delivers in a distribution panel

The C40R46E400 is a Schneider Electric ComPacT NSX400R molded case circuit breaker with a 400 A MicroLogic 6.3 E electronic trip unit, rated for distribution duty. The 4-pole construction with neutral on the left suits it for three-phase plus neutral distribution in a backplate-mounted panel.

Trip unit and protection logic

The MicroLogic 6.3 E provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection, all configurable via the front LCD display. That matters for a pump or compressor that trips on overload and gets restarted before the windings have shed the heat.

The R breaking capacity code means 200 kA Icu at 415 V AC, and the same 200 kA holds at 220/240 V and 440 V. At 500 V it drops to 80 kA, at 525 V to 65 kA, and at 690 V to 45 kA.

Durability and mounting

Mechanical durability is 15 000 cycles; electrical durability at 440 V full-rated current is 6 000 cycles, and at half-rated current (200 A) it reaches 12 000 cycles. At 690 V the electrical endurance drops to 3 000 cycles at full current and 6 000 at half current. Mounting is horizontal or vertical on a backplate, with front-facing connections on both the line and load sides. The 185 mm width and 110 mm depth fit a standard distribution cubicle, and the IK07 impact rating means it survives a hammer strike during panel assembly without the enclosure cracking.

Frequently asked questions

What is C40R46E400's listed range on this component line?

It belongs to the Schneider Electric ComPacT NSX range, specifically the NSX400R device short name.