Skip to main content
Schneider Electric C60H1P10AC — 1-Pole MCB (DIN Rail)

Schneider Electric C60H1P10AC MCB, C Curve, 10 A, 1P, Multi9

MPNC60H1P10AC
Obsolete

Schneider Electric Multi9 C60H, C60H1P10AC, miniature circuit breaker, 1P, 10 A, C curve, 15 kA at 230 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P10AC — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P10AC — Electrical & Protection
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P10AC — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H1P10AC — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P10AC — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H1P10AC is a 1-pole miniature circuit breaker from the Multi9 C60 range, rated 10 A at 30 °C with a C tripping curve (5...10 x In magnetic limit). The thermal-magnetic trip unit handles overloads and short-circuits in one compact package.

Breaking capacity and voltage ratings

Breaking capacity varies by voltage: 15 kA Icu at 230...240 V AC, 30 kA at 130 V AC, 4 kA at 400...415 V AC, and 20 kA at 60 V DC (all per IEC 60947-2). Rated operational voltage is 440 V AC, with insulation rated at 500 V AC. Impulse withstand voltage is 6 kV. For a 10 A feeder in a 230 V panel, the 15 kA Icu gives solid fault clearance without cascading upstream.

Physical integration

Dimensions: 81 mm high, 18 mm wide, 73 mm deep. Fixed mounting on 35 mm DIN rail. Toggle actuation with ON/OFF indication and a contact position indicator. Suitability for isolation confirmed per IEC 60947-2.

Environmental and durability

Mechanical durability rated at 20,000 cycles.

Frequently asked questions

What is the breaking capacity of C60H1P10AC at 230 V?

The C60H1P10AC has a breaking capacity of 15 kA Icu at 230...240 V AC per IEC 60947-2.

What is the closest alternative to C60H1P10AC in the Multi9 range?

Within the same C60 family, the C60H1P10AC is a 1-pole, 10 A, C-curve unit. Siblings differ by poles (2P, 3P, 4P), rated current (higher or lower), or curve (B, D). The deciding factor is your load type and fault level — for motor starting or transformer inrush, a D curve may be needed; for general lighting and socket circuits, the C curve is standard.

How do I get current pricing and availability for C60H1P10AC?

Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time based on current distributor inventory.

MPN