C60H1P16AB MCB, 16 A, Curve B, 1P, 15 kA

MPNC60H1P16AB
Obsolete

Schneider Electric, Multi9 series, C60H miniature circuit breaker, C60H1P16AB, 16 A, B-curve, 1-pole, 15 kA breaking capacity at 230-240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P16AB — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P16AB — Electrical & Protection
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P16AB — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H1P16AB — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P16AB — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The C60H1P16AB is a 1-pole miniature circuit breaker from the Schneider Electric Multi9 range, rated 16 A at 30 °C with a B-curve (magnetic trip 3–5 × In). The 73 mm depth leaves room for gland plates and cable bends in a compact enclosure.

Rated breaking capacity (Icu) hits 15 kA at 230–240 V AC, 20 kA at 60 V DC, and 4 kA at 400–415 V AC per IEC 60947-2. For selectivity studies, the B-curve's 3–5× In magnetic threshold gives a wider gap upstream of C-curve or D-curve devices.

Fixed mounting on 35 mm DIN rail. The toggle provides local ON/OFF indication and a contact position indicator confirms isolation status — suitable for lockout/tagout verification per IEC 60947-2.

Frequently asked questions

Where can I buy C60H1P16AB and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the closest pin-compatible alternative to C60H1P16AB?

Within the same Multi9 C60 family, the C60H1P16AB is the standard 16 A B-curve 1-pole variant. A C60N or C60L version would differ in breaking capacity (lower or higher Icu), not in footprint or wiring — check the required SCCR before substituting.

What compliance documentation does this brand provide for C60H1P16AB?

The breaker is designed to IEC 60947-2 (limitation class 3, isolation suitability) and IEC 60068-1 (tropicalisation class 2). Typical documentation includes a declaration of conformity, IEC test reports, and a CE declaration — request these with your RFQ.

MPN
C60H1P16AB