Skip to main content
Schneider Electric C60H1P16AD

C60H1P16AD MCB, Multi9, D-curve, 16 A, 1P, 15 kA

MPN C60H1P16AD
Obsolete

Schneider Electric Multi9 C60 series, C60H1P16AD miniature circuit breaker, D-curve, 16 A, 1 pole, 15 kA breaking capacity at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H1P16AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width18 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H1P16AD is a 1-pole miniature circuit breaker from the Multi9 range, rated 16 A at 40 °C with a D tripping curve (magnetic trip threshold 10–14 × In). That D-curve is the deciding factor for fit: it holds through the inrush of motor starters, small transformers, and solenoid banks where a C-curve would nuisance-trip on the magnetizing peak. The thermal-magnetic trip unit gives you the bimetal for sustained overloads and the solenoid for short-circuit — no electronics to drift, no auxiliary supply needed. Breaking capacity is 15 kA Icu at 230 V AC (IEC 60947-2), which means it safely interrupts a fault up to that level without welding the contacts or cascading upstream; the Ics (service breaking capacity) is the same 15 kA at 440 V AC, so it can reclose after a fault at full rated interrupting duty — not all MCBs carry that.

Panel integration — DIN rail and fill factor

Width is 18 mm (2 × 9 mm pitches). Depth is 73 mm.

Rated insulation voltage 500 V AC, operational voltage 440 V AC, impulse withstand 6 kV. Limitation class 3 conforming to IEC 60947-2.

MPN