Skip to main content
Schneider Electric C60H1P3AD — 1-Pole MCB (DIN Rail)

Schneider Electric C60H1P3AD C60 MCB, 3 A, D Curve, 1P, 15 k

MPNC60H1P3AD
Obsolete

Schneider Electric Multi9 C60 series, C60H1P3AD miniature circuit breaker, 1 pole, 3 A, D curve, 15 kA breaking capacity at 230 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P3AD — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P3AD — Electrical & Protection
ParameterValue
Rated current (In)3 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P3AD — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H1P3AD — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P3AD — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H1P3AD is a 1-pole miniature circuit breaker from the Multi9 C60 range, rated 3 A with a D tripping curve.

Rated breaking capacity (Icu) hits 15 kA at 230...240 V AC per IEC 60947-2, and 20 kA at 60 V DC on a single pole. At 400...415 V AC it drops to 4 kA — still enough for most final subcircuits in a 400 V distribution board, but you'll want to check the upstream device's let-through if your fault current at that voltage exceeds 4 kA.

Occupies 2 modules of 9 mm pitch (18 mm wide) on the DIN rail. Depth is 73 mm, height 81 mm. The toggle gives local ON/OFF indication, and the contact position indicator shows the true state of the contacts — useful during panel commissioning when the handle might be locked off.

Environmental and isolation specs

Tropicalisation level 2 per IEC 60068-1 handles humidity up to 95% at 55 °C — fine for coastal or unconditioned plant rooms. Impulse withstand voltage is 6 kV.

Frequently asked questions

Where can I buy the C60H1P3AD and how is it quoted?

We source the C60H1P3AD to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit the order code for a firm quotation.

What is the C60H1P3AD's depth?

The C60H1P3AD has a depth of 73 mm, with a width of 18 mm (2 x 9 mm modules) and height of 81 mm.

What range does the C60H1P3AD belong to?

It belongs to the Schneider Electric Multi9 C60 range, a widely used family of miniature circuit breakers for distribution applications.

What compliance documentation is available for the C60H1P3AD?

The breaker is designed to IEC 60947-2 standards, with tropicalisation per IEC 60068-1. It carries suitability for isolation marking and limitation class 3 per IEC 60947-2. Specific RoHS, REACH, or UL documentation should be requested at quote time as it varies by production batch and region.

MPN