C60H1P40AB — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P40AB — Electrical & Protection
ParameterValue
Rated current (In)40 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P40AB — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)3.5 N.m
C60H1P40AB — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P40AB — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The C60H1P40AB is a 1-pole 40 A miniature circuit breaker from Schneider's Multi9 C60H range, B-curve characteristic. It occupies 2 x 9 mm module pitches (18 mm width) on a 35 mm symmetrical DIN rail, fixed mounting. Breaking capacity is 15 kA Icu at 230...240 V AC (IEC 60947-2), with a corresponding Ics service breaking capacity of 15 kA at 12...440 V AC. At 400...415 V AC the Icu drops to 4 kA, so for three-phase panel feeders this unit is best applied on single-phase branch circuits or as a backup device coordinated with an upstream higher-rated breaker. Rated operational voltage is 440 V AC, insulation voltage 500 V AC, impulse withstand 6 kV.

Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible conductors, strip length 14 mm, tighten to 3.5 N·m. Ambient operating range is -25 to 60 °C, storage -40 to 70 °C, with 95 % RH at 55 °C. Tropicalisation level 2 per IEC 60068-1 means the unit is treated for high-humidity environments — suitable for coastal or unconditioned plant rooms.

Frequently asked questions

What is the breaking capacity of C60H1P40AB?

15 kA Icu at 230...240 V AC, 20 kA Icu at 60 V DC (1-pole), and 30 kA Icu at 130 V AC, all per IEC 60947-2. At 400...415 V AC the Icu is 4 kA. The Ics service breaking capacity is 15 kA at 12...440 V AC.

What does the B-curve mean on this breaker?

The B-curve (magnetic trip 3 to 5 x In) means the breaker trips instantaneously between 120 A and 200 A. It is designed for resistive loads and light inductive loads where inrush is low, such as lighting circuits, socket outlets, and general-purpose distribution.

Where can I buy C60H1P40AB?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.