Skip to main content
Schneider Electric C60H1P4AD

Schneider Electric C60H1P4AD C60 MCB, 1P, 4A, D Curve

MPN C60H1P4AD
Obsolete

Schneider Electric Multi9 C60, C60H1P4AD, miniature circuit breaker, 1-pole, 4 A rated current, D curve, 15 kA breaking capacity at 230 V AC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H1P4AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width18 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H1P4AD is a 1-pole miniature circuit breaker from the Multi9 C60 series, rated 4 A at 40 °C with a D tripping curve. The D curve means its magnetic trip operates between 10 and 14 times the rated current (40 to 56 A instantaneous trip), making it the right choice for loads with high inrush — think motor starters, small transformers, or discharge lighting where a B or C curve would nuisance-trip on startup. The thermal-magnetic trip unit handles the overload side. Breaking capacity is 15 kA Icu at 230...240 V AC (IEC 60947-2), which covers most commercial and light industrial distribution panels. At 400...415 V AC the rating drops to 4 kA — still adequate for sub-distribution in a 400 V system where the upstream device limits fault current.

The 18 mm width (2 x 9 mm pitches) means it occupies a single module slot in a standard distribution board — no surprises for panel fill calculations. Depth is 73 mm, height 81 mm. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible cable; strip length is 14 mm, tighten to 2 N·m.

Rated operational voltage (Ue): 440 V AC. Rated insulation voltage (Ui): 500 V AC. Impulse withstand (Uimp): 6 kV. Tropicalisation class 2 per IEC 60068-1, limitation class 3 per IEC 60947-2. Operating temperature range -25 to 60 °C, storage -40 to 70 °C. Mechanical durability: 20,000 cycles.

MPN
C60H1P4AD