Skip to main content
Schneider Electric C60H1P50AD — 1-Pole MCB (DIN Rail)

C60H1P50AD Miniature Circuit Breaker, D Curve, 50 A, 1P

MPNC60H1P50AD
Obsolete

Schneider Electric C60H1P50AD, Multi9 C60H series, 1-pole miniature circuit breaker, D curve, 50 A rated current, 10 kA Icn at 230/400 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P50AD — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P50AD — Electrical & Protection
ParameterValue
Rated current (In)50 A at 40 °C
Rated operational voltage (Ue)12...440 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P50AD — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 3.5 N.m upside 3.5 N.m downside
C60H1P50AD — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P50AD — Approvals
ParameterValue
Conformity standardsEN 60898 IEC 60947-2
C60H1P50AD — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H1P50AD is a 1-pole miniature circuit breaker from the Multi9 C60H series, rated 50 A at 40 °C with a D tripping curve.

Breaking capacity is 10 kA Icn at 230/400 V AC per EN 60898, and 15 kA Icu at 230–240 V AC per IEC 60947-2. For DC circuits, it handles 20 kA at 60 V DC (1P). These ratings let the C60H1P50AD serve as a main or branch breaker in a residential or light commercial panel, provided the prospective fault current stays within its envelope.

Installation and compliance

The breaker is certified to EN 60898 and IEC 60947-2, with tropicalisation per IEC 60068-1 (2 levels) and limitation class 3 per IEC 60947-2. The toggle provides local ON/OFF indication and a contact position indicator confirms the state of the main contacts.

Frequently asked questions

Where can I buy C60H1P50AD and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock or price figures are published here.

What does the D curve mean on this breaker?

The D curve trips magnetically at 10–14 times the rated current (In). For the C60H1P50AD at 50 A, that means instantaneous trip between 500 A and 700 A. This suits loads with high inrush like motors, transformers, and welding equipment.

What is the breaking capacity at 400 V?

At 400–415 V AC, the Icu per IEC 60947-2 is 4 kA, and the Ics (service breaking capacity) is 2 kA. At 230/400 V AC per EN 60898, the Icn is 10 kA.

MPN
C60H1P50AD