Skip to main content
Schneider Electric C60H1P63AB — 1-Pole MCB (DIN Rail)

Schneider C60H1P63AB MCB, 63A Curve B, 1P, Multi9

MPNC60H1P63AB
Obsolete

Schneider Electric C60H1P63AB, Multi9 C60H series, 1-pole miniature circuit breaker, 63 A rated current, B-curve, 10 kA Icn per EN 60898, 15 kA Icu at 230 V AC per IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H1P63AB — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60H1P63AB — Electrical & Protection
ParameterValue
Rated current (In)63 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H1P63AB — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 3.5 N.m upside 3.5 N.m downside
C60H1P63AB — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H1P63AB — Approvals
ParameterValue
Conformity standardsEN 60898 IEC 60947-2
C60H1P63AB — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H1P63AB is a 1-pole miniature circuit breaker from the Multi9 C60H series, rated 63 A at 30 °C with a B-curve (magnetic trip between 3 and 5 times In). The B-curve means the magnetic trip activates at 3 to 5 times the rated current — 189 A to 315 A for this 63 A unit — making it suited for resistive or general-purpose loads where inrush is moderate, not for motor-starting or transformer primaries that would need a C or D curve.

This breaker carries dual ratings: 10 kA Icn at 230/400 V AC per EN 60898 (the standard for household-type MCBs), and 15 kA Icu at 230...240 V AC per IEC 60947-2 (the industrial standard). The IEC 60947-2 rating also gives 20 kA Icu at 60 V DC (1P) and 4 kA Icu at 400...415 V AC. For a 63 A feed in a typical 230 V single-phase distribution board, the 10 kA Icn covers most utility fault levels.

Integration notes — DIN rail and wiring

Snaps onto 35 mm symmetrical DIN rail.

Frequently asked questions

What is the breaking capacity of C60H1P63AB?

It has 10 kA Icn at 230/400 V AC per EN 60898 and 15 kA Icu at 230...240 V AC per IEC 60947-2. At 400...415 V AC the Icu is 4 kA, and at 60 V DC it is 20 kA (1 pole).

Where can I buy the C60H1P63AB?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

What compliance documentation does Schneider provide for C60H1P63AB?

The breaker is certified to EN 60898 and IEC 60947-2. It carries a CE marking for the European market and is suitable for isolation per IEC 60947-2. Specific RoHS/REACH declarations are available from Schneider Electric upon request.

MPN
C60H1P63AB