Schneider Electric C60H2P10AB — 1-Pole MCB (DIN Rail)

C60H2P10AB Miniature Circuit-Breaker, 10 A, Curve B, 1P+N, M

MPNC60H2P10AB
Obsolete

Schneider Electric Multi9 C60H, miniature circuit-breaker C60H2P10AB, 1P+N, 10 A rated, curve B, 10 kA breaking capacity at 440 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P10AB — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P10AB — Electrical & Protection
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P10AB — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H2P10AB — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P10AB — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The C60H2P10AB is a 1P+N miniature circuit-breaker from the Multi9 C60 range, rated 10 A at 30 °C with a B-curve trip characteristic (magnetic trip between 3 and 5 times In). That B-curve means it trips fast on moderate overloads — good for resistive or general-purpose loads where you want to protect wiring, not for motor starting where the inrush would nuisance-trip it. That's another SKU I don't need to second-guess on the shelf.

Deployment context

This breaker lives in a distribution board — typically a sub-distribution panel feeding lighting, socket outlets, or small resistive loads. The 1P+N configuration switches the phase and protects it, with the neutral on the left (fixed position) and unswitched. The toggle gives local ON/OFF indication; the contact position indicator confirms isolation visually.

Altitude rating is 2000 m standard; above that you'd need to derate.

Frequently asked questions

How do I get current pricing and availability for C60H2P10AB?

Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront; we source through independent distribution channels and can quote current market pricing and lead time.

What is the closest alternative to C60H2P10AB in the same family?

Within the Multi9 C60 range, the closest sibling is the C60H2P10AC (same 10 A, 1P+N, same breaking capacity, but with a C-curve for moderate inrush loads like small motors or transformers). The physical footprint, terminal capacity, and DIN rail mounting are identical — the only difference is the magnetic trip threshold (5-10 x In for C-curve vs 3-5 x In for B-curve). Choose B for resistive/lighting circuits; choose C for mixed loads with some motor or transformer inrush.

What compliance documentation does Schneider provide for C60H2P10AB?

The C60H2P10AB is designed and tested to IEC 60947-2 (breaking capacity, limitation class, isolation suitability). It carries tropicalisation per IEC 60068-1. Standard Schneider documentation includes the datasheet, installation instructions, and declaration of conformity covering the applicable EU directives. For specific RoHS/REACH declarations, refer to the manufacturer's product compliance portal using the full order code.