Schneider Electric C60H2P16AB — 1-Pole MCB (DIN Rail)

Schneider Electric C60H2P16AB MCB, C60 Multi9, B Curve 16A 1

MPNC60H2P16AB
Obsolete

Schneider Electric C60H2P16AB, Multi9 C60 range, miniature circuit breaker, B curve, 16 A, 1P+N, 10-30 kA breaking capacity, 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P16AB — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P16AB — Electrical & Protection
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P16AB — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H2P16AB — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P16AB — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H2P16AB is a C60H-series miniature circuit breaker from the Multi9 range, rated 16 A at 30 °C with a B tripping curve (3–5 × In magnetic trip). It protects a single pole with a switched neutral (1P+N), making it a common choice for single-phase final subcircuits in distribution boards where the neutral is switched alongside the phase. Breaking capacity reaches 30 kA Icu at 230–240 V AC and 10 kA Icu at 440 V AC, both per IEC 60947-2. The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (magnetic solenoid) in one compact package.

The 36 mm width (4 modules at 9 mm pitch) fits standard distribution board cutouts. Fixed mounting mode — no plug-in base, so it stays put under vibration or during busbar connection. The neutral position is left, which matches the typical busbar layout in Multi9 boards. Depth of 73 mm and height of 81 mm leave clearance for wiring and enclosure covers. The toggle actuator provides local ON/OFF indication and manual switching.

Rated insulation voltage 500 V AC, operational voltage 440 V AC. Mechanical durability rated at 20,000 cycles.

Frequently asked questions

What is the breaking capacity of the C60H2P16AB?

Breaking capacity is 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, and 10 kA at 440 V AC, all per IEC 60947-2. For DC applications, it is rated 25 kA at 125 V DC (2-pole series connection).

What does the B curve mean on this breaker?

The B curve means the magnetic trip operates at 3 to 5 times the rated current (48–80 A for this 16 A unit). It is typically used for resistive or general-purpose loads where inrush is low — lighting, small transformers, control circuits.

Where can I buy the C60H2P16AB?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What compliance documentation is available for the C60H2P16AB?

The breaker is designed to IEC 60947-2 (breaking capacity, limitation class 3, isolation suitability) and IEC 60068-1 (tropicalisation). Standard Schneider Multi9 documentation includes CE declaration and RoHS/REACH compliance data available on request.

MPN
C60H2P16AB