Skip to main content
Schneider Electric C60H2P16AC — 1-Pole MCB (DIN Rail)

C60H2P16AC Miniature Circuit-Breaker, C Curve, 16 A, Multi9

MPNC60H2P16AC
Obsolete

Schneider Electric Multi9 C60H, miniature circuit-breaker, 1P + N, 16 A, C curve, 10 kA breaking capacity at 440 V AC, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P16AC — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P16AC — Electrical & Protection
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P16AC — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H2P16AC — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P16AC — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The C60H2P16AC is a 1P + N miniature circuit-breaker from Schneider Electric's Multi9 C60 range, rated 16 A at 30 °C with a C trip curve (5–10 × In magnetic tripping limit). Breaking capacity is 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, and 10 kA at 440 V AC, all conforming to IEC 60947-2. At 125 V DC (2 poles) it delivers 25 kA Icu. That range of SCCR values lets you coordinate selectivity across different fault levels in the distribution panel without oversizing the branch breaker. The separate earth-leakage block (Vigi add-on) is ordered independently when ground-fault protection is required.

Frequently asked questions

What is the breaking capacity of C60H2P16AC at 400 V?

At 400–415 V AC, the breaking capacity is 15 kA Icu conforming to IEC 60947-2.

What is the closest alternative to C60H2P16AC in the same family?

Within the C60 range, the closest alternative is a different current rating or pole configuration — the C60H2P16AC is a 1P + N, 16 A, C-curve variant. For a 2-pole version at the same current, look at the C60H-DIN series; for a different trip curve (B or D), the C60H prefix remains the same but the curve code changes.

What compliance documentation does Schneider provide for C60H2P16AC?

The MCB carries IEC 60947-2 certification for breaking capacity and isolation suitability. Tropicalisation conforms to IEC 60068-1 class 2. Standard declarations (CE, UKCA, RoHS) are available through Schneider's documentation portal for the Multi9 range.

Where can I buy C60H2P16AC and how is it quoted?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest commercial terms.

MPN
C60H2P16AC