Schneider Electric C60H2P1AC — 1-Pole MCB (DIN Rail)

Schneider Electric C60H2P1AC MCB, C Curve, 1P+N, 1 A, 10 kA

MPNC60H2P1AC
Obsolete

Schneider Electric Multi9 C60H, C60H2P1AC, miniature circuit breaker, 1P+N, C curve, 1 A, 10 kA Icu at 440 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P1AC — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P1AC — Electrical & Protection
ParameterValue
Rated current (In)1 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P1AC — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
C60H2P1AC — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P1AC — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H2P1AC is a 1P+N miniature circuit breaker from the Multi9 C60 range, rated 1 A with a C curve (magnetic trip at 5–10 x In). The 1 A rating protects a low-current branch; at 30 °C ambient it carries 1 A continuously, and the thermal-magnetic trip handles both overload and short-circuit conditions. Breaking capacity is 10 kA Icu at 440 V AC per IEC 60947-2, with higher ratings at lower voltages: 15 kA at 400–415 V AC, 30 kA at 230–240 V AC. For a 1 A MCB on a typical 230/400 V distribution board, the 10 kA at 440 V is the limiting figure — it confirms the breaker can safely interrupt a fault up to that level without welding contacts or cascading upstream. The 25 kA DC rating at 125 V DC (2P series-connected) is available if the same frame is used in a DC sub-panel. The 1P+N configuration protects the phase only; the neutral pole is switched but not protected. That's standard for single-phase final circuits where the neutral is solidly bonded at the distribution board. The neutral position is left, matching the typical busbar arrangement in Schneider distribution boards.

At 4 module pitches (36 mm wide per module, so 144 mm total), it occupies four 18 mm slots in a standard distribution board. Depth is 73 mm, height 81 mm — check enclosure fill factor if the board is tight, but the footprint is standard for a 1P+N MCB in the Multi9 family. The contact position indicator and ON/OFF local signalling give a quick visual check during commissioning or troubleshooting.

Frequently asked questions

What is C60H2P1AC's breaking capacity at 440 V AC?

The C60H2P1AC has a breaking capacity of 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2. At 230–240 V AC the rating rises to 30 kA Icu.

What does the C curve mean on this MCB?

The C curve means the magnetic trip operates at 5–10 times the rated current (In). For a 1 A breaker, that's 5–10 A instantaneous trip — suitable for general-purpose distribution circuits with moderate inrush, like lighting and small transformers.

MPN