Schneider Electric C60H2P32AD — 1-Pole MCB (DIN Rail)

Schneider Electric C60H2P32AD MCB, D Curve, 32 A, 1P+N

MPNC60H2P32AD
Obsolete

Schneider Electric Multi9 C60H series, C60H2P32AD miniature circuit breaker, D curve, 32 A, 1P+N, 10-30 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P32AD — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P32AD — Electrical & Protection
ParameterValue
Rated current (In)32 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P32AD — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)3.5 N.m
C60H2P32AD — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P32AD — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

What this MCB does on a DIN rail

The C60H2P32AD is a 1P+N miniature circuit breaker from the Multi9 C60H series, rated 32 A at 40 °C with a D tripping curve. Breaking capacity hits 30 kA at 230–240 V AC and 15 kA at 400–415 V AC, so it handles substantial fault currents in distribution panels.

D curve — why it matters for motor and transformer circuits

Standard B or C curve MCBs can nuisance-trip on the startup surge of a motor or transformer. The D curve's 10–14 x In window lets that inrush pass without opening, while still clearing a hard short. For a 32 A breaker, that means magnetic hold-up to roughly 320–448 A peak before the solenoid fires. Thermal-magnetic trip technology handles the overload side with a bimetal strip.

Panel integration — what fits where

Width is 36 mm (4 x 9 mm pitches). Depth 73 mm, height 81 mm. Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible copper; strip length 14 mm, tighten to 3.5 N·m. Neutral position is left. The toggle gives local ON/OFF indication and a contact position indicator confirms isolation status — it's certified for isolation per IEC 60947-2.

Frequently asked questions

Where can I buy C60H2P32AD and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to C60H2P32AD in the same family?

Within the Multi9 C60H series, the C60H2P32AD is the 32 A D-curve 1P+N variant. A C60H2P32B would offer the same current and poles with a B curve for general-purpose loads; a C60H2P32C gives a C curve for moderate inrush. No pin-compatible drop-in exists outside the D curve.

What compliance documentation does Schneider provide for C60H2P32AD?

The breaker carries IEC 60947-2 certification for breaking capacity and isolation suitability. Tropicalisation per IEC 60068-1 is class 2. Limitation class 3 per IEC 60947-2. RoHS/REACH declarations are standard for the Multi9 range.