Skip to main content
Schneider Electric C60H3P16AB

Schneider Electric C60H3P16AB MCB, C60H, 3P, 16 A, B Curve

MPN C60H3P16AB
Obsolete

Schneider Electric Multi9 C60H, C60H3P16AB, miniature circuit breaker, 3-pole, 16 A, B curve, 10-40 kA breaking capacity, 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P16AB specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

What this MCB delivers

The C60H3P16AB: Breaking capacity is the headline here: 30 kA Icu at 230...240 V AC, 15 kA at 400...415 V AC, and 10 kA at 440 V AC, all per IEC 60947-2. That means it can handle high-fault panels where a standard 10 kA MCB would weld. For motor or transformer circuits, a C or D curve would be a better fit — this one is for general distribution where the inrush stays under 80 A.

Snaps onto a 35 mm symmetrical DIN rail, occupies 6 x 9 mm pitches (54 mm wide), and stands 81 mm tall with a depth of 73 mm. That depth is the body only — allow clearance for the toggle throw and outgoing cables. Earth-leakage protection requires a separate block; this is the thermal-magnetic only.

Rated for operation from -25 to 60 °C, storage from -40 to 70 °C, and 95 % relative humidity at 55 °C. Tropicalisation level 2 per IEC 60068-1 means it handles damp-heat cycling without internal corrosion — relevant for coastal or unconditioned plant rooms. Altitude limit is 2000 m; above that, derate the breaking capacity. The limitation class is 3 per IEC 60947-2, which limits let-through energy under fault; this helps with downstream coordination in a selective scheme.

MPN
C60H3P16AB