Skip to main content
Schneider Electric C60H3P25AB — 2-Pole MCB (DIN Rail)

Schneider C60H3P25AB MCB, 3P, 25A, Curve B, 10kA

MPNC60H3P25AB
Obsolete

Schneider Electric, Multi9 range, C60H3P25AB, miniature circuit-breaker, 3P, 25 A, B-curve, 10 kA breaking capacity at 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P25AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P25AB — Electrical
ParameterValue
Rated current [In]25 A at 30 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P25AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P25AB — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P25AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The Schneider Electric C60H3P25AB is a 3-pole miniature circuit breaker from the Multi9 C60 range, rated 25 A with a B-curve trip characteristic.

Depth is 73 mm, height 81 mm. The 14 mm strip length is standard for this terminal class. The toggle gives a clear ON/OFF indication, and the contact position indicator confirms isolation status — useful when locking out for downstream work.

The C60H3P25AB carries a 30 kA Icu at 230–240 V AC and 10 kA at 440 V AC, with a service breaking capacity (Ics) of 15 kA at 400–415 V. That Ics figure — 100% of Icu at the lower voltage — means the breaker can be reclosed after a fault at that level without immediate replacement, which matters for uptime in continuous-process panels. The B-curve (3–5× In magnetic trip) coordinates well with upstream S-curve or selective breakers in a typical two-level distribution scheme.

Tropicalisation level 2 per IEC 60068-1 handles 95% RH at 55 °C. Limitation class 3 per IEC 60947-2 means it lets through limited energy under short-circuit — helps protect downstream equipment.

Frequently asked questions

What is the breaking capacity of the C60H3P25AB?

The C60H3P25AB has a rated ultimate breaking capacity (Icu) of 10 kA at 440 V AC, 15 kA at 400–415 V AC, 30 kA at 230–240 V AC, and 25 kA at 125 V DC (2-pole series connection) per IEC 60947-2. The service breaking capacity (Ics) is 15 kA at 400–415 V AC.

What terminals does the C60H3P25AB accept?

Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible copper conductors. Tightening torque is 2 N·m, and the recommended strip length is 14 mm.

Where can I buy the C60H3P25AB and how is it quoted?

The C60H3P25AB is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the closest alternative to the C60H3P25AB in the same family?

Within the Multi9 C60 range, the closest alternative is the C60H-DC variant if DC application is needed, or a different curve (C or D) for higher inrush loads. For the same 25 A, 3-pole, B-curve configuration, the C60H3P25AB is the standard catalogue code; no pin-compatible drop-in with different ratings exists in the same form factor.

MPN